F1100-90(1997) Standard Specification for Ventilators Intended for Use in Critical Care (Withdrawn 2004)

Published By Publication Date Number of Pages
ASTM 1997 13
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM F1100-90-Reapproved1997

Withdrawn Standard: Standard Specification for Ventilators Intended for Use in Critical Care (Withdrawn 2004)

ASTM F1100

Scope

1.1 General -This specification establishes minimum performance and safety requirements for all ventilators and ventilator circuits intended for use with adult, child, or infant patients in critical care within the hospital and introduced for sale after the acceptance date of this specification, except as noted below. Definitions, performance requirements, test methods, and rationale are included. Several definitions have been included in Section 3.1 and Appendix X1 that are not used in the text of this specification. This material has been included for the sake of completeness, and for any possible educational benefit that may be served.

1.2 Exclusions -This specification does not apply to body ventilators such as the tank ventilator or the chest cuirass nor does it apply to ventilators utilizing the Sanders technique or “jet” ventilation, (venturi effect type) high frequency ventilators (greater than 2.5 Hz), or anesthesia ventilators. This specification does not apply to ventilators intended for use in transport applications or home care, nor does it apply to those ventilators developed for veterinary applications. The application of critical care ventilators in the home environment is not covered by this specification nor is the hospital use of transport or home care ventilators. (See also Appendix X2.1.)

1.3 The following precautionary caveat pertains to the test methods portion only, Section 6, of this specification: This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

critical patient care; hospitals; patient care; performance-medical materials/applications; safety precautions-medical materials/applications; ventilators; ventilators for use in critical care

ICS Code

ICS Number Code 23.120 (Ventilators. Fans. Air-conditioners)

DOI: 10.1520/F1100-90R97

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
3 Materials and Manufacture
Performance Requirements
TABLE 1
4 TABLE 2
TABLE 3
FIG. 1
6 Test Methods
FIG. 2
7 FIG. 3
TABLE 4
TABLE 5
8 TABLE 6
9 Warnings and Markings
Operation and Maintenance Manual
10 X1. CLASSIFICATION AND TYPES OF BREATHING MACHINES
X1.1
X1.2
X1.3
X1.4
X1.5
X1.6
X1.7
X1.8
11 X2. RATIONALE
X2.1 Scope
X2.2
X2.3
ASTM-F1100
$44.96