District heating pipes. Bonded single and twin pipe systems for buried hot water networks. Surveillance systems
Published By | Publication Date | Number of Pages |
BSI | 2019 | 30 |
This document specifies requirements and test methods for surveillance systems for directly buried hot water networks in accordance with EN 13941?1 and EN 13941?2.
This document specifies requirements for the manufacture of measuring elements, for the manufacture of factory made bonded pipe, fitting and valve assemblies with measuring elements as well as for the assembly of the measuring elements in the field.
All requirements and recommendations described in this document are based on the experience gained with existing surveillance systems and their principle function.
The specific requirements given are only valid for electrical wire based surveillance systems forming an integral part of the pipes, valves, fittings and joints.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | European foreword |
7 | Introduction |
8 | 1 Scope 2 Normative references 3 Terms and definitions 4 Basic functional requirements 4.1 Dependency of manufacturer of pipe elements 4.2 Performance |
9 | 5 Manufacture of measuring elements 5.1 General requirements 5.2 Installation, assembly and operation 5.3 Characteristics 5.4 Reliability 5.5 Maintenance 5.6 Longitudinal tightness 5.7 Marking of measuring elements 5.8 Technical documentation 5.8.1 General 5.8.2 For installation of measuring wires within pipe elements 5.8.3 For assembly of measuring elements in the field 5.8.4 For operation of a surveillance system |
10 | 6 Manufacture of pipe elements with measuring elements 6.1 General requirements 6.2 Compatibility test 6.2.1 Before series production 6.2.2 Test procedure 6.2.3 Replication of test 6.3 Installation of measuring elements 6.3.1 Restrictions regarding type of measuring element 6.3.2 No electrical contact 6.3.3 Connections 6.3.4 Geometry of installation |
11 | 6.3.5 Spacers 6.3.6 Mechanical tightening 6.4 After pipe element manufacturing 6.5 Measuring wires at free ends 6.5.1 Wire length 6.5.2 Protection of measuring wires 6.6 Tests 6.6.1 General 6.6.2 Continuity of measuring wire 6.6.3 No electrical contact 6.7 Quality control programme |
12 | 6.8 Technical documentation 6.8.1 General 6.8.2 For assembly of measuring elements in the field 6.8.3 For operation of a surveillance system 7 Assembly of measuring elements in field 7.1 Check upon receipt of pipe elements 7.2 Extension of an existing measuring section 7.2.1 Actual state 7.2.2 Change of system 7.3 Wiring design diagram 7.4 Assembly work in joints |
13 | 7.5 Assembly check 7.6 Test after finishing a measuring section 7.6.1 General 7.6.2 Continuity of measuring elements 7.6.3 No electrical contact and moisture 7.6.4 Functional test 7.7 Test and measurement during system operation 7.8 Quality control programme |
14 | 7.9 Technical documentation |
15 | Annex A (informative) Principal function |
16 | Annex B (informative) Principal parts of a measuring section |
17 | Annex C (normative) Technical documentation |
20 | Annex D (normative) Loop test by pipe manufacturer |
22 | Annex E (normative) High voltage test by pipe manufacturer |
23 | Annex F (informative) Quality control programme |
25 | Annex G (normative) Loop test in field |
26 | Annex H (normative) Measuring of the electrical insulation resistance in field |
27 | Annex I (informative) Waste treatment and recycling |
28 | Bibliography |