Shopping Cart

No products in the cart.

BS EN 15703-2:2014

$102.76

Copper and copper alloys. Determination of manganese content – Flame atomic absorption spectrometric method (FAAS)

Published By Publication Date Number of Pages
BSI 2014 18
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies a flame atomic absorption spectrometric method (FAAS) for the determination of the manganese content of copper and copper alloys in the form of unwrought, wrought and cast products.

The method is applicable to products having manganese mass fractions between 0,001 0 % and 6,0 %.

PDF Catalog

PDF Pages PDF Title
4 Contents Page
5 Foreword
6 1 Scope
2 Normative references
3 Principle
4 Reagents
4.1 Hydrochloric acid, HCl (ρ = 1,19 g/ml)
4.2 Nitric acid, HNO3 (ρ = 1,40 g/ml)
4.3 Hydrofluoric acid, HF (ρ = 1,13 g/ml)
4.4 Nitric acid solution, 1 + 1
4.5 Lanthanum(III) chloride solution, 100 g/l
4.6 Sulphuric acid, H2SO4 (ρ = 1,84 g/ml)
7 4.7 Sulphuric acid solution, 1 + 9
4.8 Manganese stock solution, 1,0 g/l Mn
4.8.1 Cleaning of manganese metal
4.8.2 Preparation of stock solution
4.9 Manganese standard solution, 0,10 g/l
4.10 Manganese standard solution, 0,010 g/l
4.11 Copper matrix solution, 20 g/l Cu
4.12 Copper matrix solution, 2 g/l Cu
5 Apparatus
5.1 Atomic absorption spectrometer, fitted with an air/acetylene burner
8 5.2 Manganese hollow-cathode lamp
6 Sampling
7 Procedure
7.1 Preparation of the test portion solution
7.1.1 Test portion
7.1.2 Test portion solution
7.1.3 Manganese mass fractions between 0,001 % and 0,020 %
7.1.4 Manganese mass fractions between 0,020 % and 0,50 %
7.1.5 Manganese mass fractions between 0,50 % and 2,0 %
7.1.6 Manganese mass fractions between 2,0 % and 6,0 %
9 7.2 Blank test
7.3 Check test
7.4 Establishment of the calibration curve
7.4.1 Preparation of the calibration solutions
7.4.1.1 General
7.4.1.2 Manganese mass fractions between 0,001 0 % and 0,020 %
10 7.4.1.3 Manganese mass fractions between 0,020 % and 0,5 %
7.4.1.4 Manganese mass fractions between 0,5 % and 2,0 %
11 7.4.1.5 Manganese mass fractions between 2,0 % and 6,0 %
7.4.2 Adjustment of the atomic absorption spectrometer
12 7.4.3 Spectrometric measurement of the calibration solutions
7.4.4 Calibration curve
7.5 Determination
7.5.1 General
7.5.2 Preliminary spectrometric measurement
7.5.3 Spectrometric measurements
7.5.3.1 Use of the calibration curve
7.5.3.2 Use of bracketing method
8 Expression of results
8.1 Use of the calibration curve
13 8.2 Use of the bracketing method
14 9 Precision
15 10 Test report
16 Bibliography
BS EN 15703-2:2014
$102.76