Shopping Cart

No products in the cart.

BS EN 200:2023 – TC 2024

$258.95

Tracked Changes. Sanitary tapware. Single taps and combination taps for water supply systems of type 1 and type 2. General technical specification

Published By Publication Date Number of Pages
BSI 2024 136
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

This document specifies: a) the field of application for pillar taps, bib taps, single and multi-hole combination taps for use in: 1) a supply system of Type 1 (see Figure 1) with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar]; 2) a supply system of Type 2 (see Figure 2) with a pressure range of (0,01 to 1,0) MPa [(0,1 to 10) bar]; b) the dimensional, leak tightness, pressure resistance, hydraulic performance, mechanical strength, endurance, corrosion resistance of the surface of the product, sequence of testing and acoustic characteristics with which sanitary tapware products including their components (flexible hose, pullout spray) need to comply where applicable; c) test methods to verify the characteristics. The tests described in this document are type tests (laboratory tests) and not quality control or factory production control (FPC) tests carried out during manufacture. This document is applicable to draw-off taps (single taps and combination taps) for use with sanitary appliances installed in rooms used for personal hygiene (cloakrooms, bathrooms etc.) and for food preparation (kitchens), i.e. for use with baths, basins, bidets, showers and sinks. This document applies to sanitary draw-off taps of nominal size 3/8ā€, 1/2″, 3/4″ and 1ā€ (PN 10). The conditions of use and classifications are given in Table 1. Table 1 – Conditions of use [ table not reproduced here ] [ figure not reporduced here ] Figure 1- Supply system of Type 1 with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar] [ figure not reporduced here ] Figure 2 – Supply system of Type 2 with a pressure range of (0,01 to 1,0) MPa [(0,1 to 10) bar] NOTE Components which are part or can be delivered with sanitary tapware products are listed in Annex C. Final materials included in the product are not covered by this document.

PDF Catalog

PDF Pages PDF Title
80 undefined
89 1 Scope
91 2 Normative references
92 3 Terms and definitions
95 4 Designation
96 5 Marking and identification
5.1 Marking
5.2 Identification
5.2.1 Identification of inlets
5.2.2 Identification of flow controls equipment
97 6 Materials
6.1 Chemical and hygiene requirements
6.2 Exposed surface condition and quality of coating
7 Backflow protection
8 Sequence of testing
9 Dimensional characteristics
9.1 General remarks
98 9.2 Inlet dimensions
100 9.3 Outlet dimensions
104 9.4 Mounting dimensions
106 9.5 Special cases
107 10 Leaktightness characteristics
10.1 Principle
10.2 Apparatus
10.3 Leaktightness of the obturator and of the tap upstream of the obturator(s) with the obturator in the closed position
10.3.1 Procedure
10.3.2 Requirements
10.4 Leaktightness downstream of the obturator
10.4.1 General
10.4.2 Procedure
108 10.4.3 Requirements
10.5 Leaktightness of manually operated diverters
10.5.1 General
10.5.2 Procedure
10.5.3 Procedure where an outlet(s) cannot be artificially closed ā€“ products for type 1 systems
109 10.5.4 Procedure where an outlet(s) cannot be artificially closed ā€“ products for type 2 systems
10.5.5 Requirements
10.6 Leaktightness and operation of diverters with automatic return (and semi-automatic type diverters)
10.6.1 General
10.6.2 Procedure ā€“ products for Type 1 systems
110 10.6.3 Procedure ā€“ products for Type 2 systems
111 10.6.4 Requirements
113 11 Pressure resistance
11.1 Principle
11.2 Apparatus
11.3 Mechanical behaviour upstream of the obturator ā€“ obturator in the closed position
11.3.1 Procedure
11.3.2 Requirement
11.4 Mechanical behaviour downstream of the obturator ā€“ obturator in the open position
11.4.1 Procedure for products for type 1 systems
11.4.2 Procedure for products for type 2 systems
114 11.4.3 Requirement
12 Hydraulic performance
12.1 General
115 12.2 Determination of flow rate ā€“ products for type 1 systems
12.2.1 Principle
12.2.2 Apparatus
12.2.3 Procedure
12.2.4 Requirements
116 12.3 Determination of flow rate ā€“ products for type 2 systems
12.3.1 Principle
12.3.2 Apparatus
117 12.3.3 Procedure
12.3.4 Requirements
118 13 Mechanical strength/torsional resistance
13.1 Principle
13.2 Apparatus
13.3 Test piece
13.4 Procedure
13.5 Requirements
14 Mechanical endurance
14.1 General
119 14.2 Endurance test for on/off flow control devices operated by rotating the control handle
14.2.1 Principle
14.2.2 Apparatus
14.2.3 Procedure
121 14.2.4 Requirement
122 14.3 Endurance test for other on/off flow control devices
14.3.1 Principle
14.3.2 Apparatus
14.3.3 Procedure
14.3.4 Requirement
14.4 Endurance of manually operated diverters
14.4.1 Principle
123 14.4.2 Apparatus
14.4.3 Procedure
14.4.4 Requirement
14.5 Endurance of diverters with automatic return
14.5.1 Principle
14.5.2 Apparatus
124 14.5.3 Procedure
14.5.4 Requirement
125 14.6 Endurance test for swivel spouts
14.6.1 Principle
14.6.2 Apparatus
14.6.3 Procedure for single outlet type
14.6.4 Procedure for divided outlet type
126 14.6.5 Requirements
127 15 Acoustic characteristics ā€” products for type 1 systems only
15.1 General
15.2 Procedure
15.2.1 Flow rate class of sanitary tapware products (with appropriate acoustic information)
15.2.2 Flow rate class of sanitary tapware products (without appropriate acoustic information)
15.3 Expression of results
128 15.3.1 Determination of acoustic group
15.3.2 Correspondence between flow rate classes and measurements
129 Annex A (informative)Pressure take-off tee
132 Annex B (informative)Minimum flow rates and test pressures according to application
133 Annex C (informative)Product components (detailed by other standards)
BS EN 200:2023 - TC 2024
$258.95