BS EN 60079-7:2015+A11:2024
$215.11
Explosive atmospheres – Equipment protection by increased safety “e”
Published By | Publication Date | Number of Pages |
BSI | 2024 | 134 |
Creating an amendment on European level to mirror the IEC interpretation sheet of IEC 60079-7:2015/ISH1:2016 which is still active at IEC.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
35 | 4.1 Level of Protection 4.2 Electrical connections 4.2.1 General |
36 | 4.2.2 Field wiring connections |
38 | 4.2.3 Factory connections |
40 | 4.2.4 External plug and socket connections for field wiring connection 4.3 Clearances |
41 | 4.4 Creepage distances |
47 | 4.5 Printed wiring boards with conformal coating, Level of Protection āecā 4.6 Solid electrical insulating materials 4.6.1 Specification |
48 | 4.6.2 Long-term thermal stability 4.7 Windings 4.7.1 General 4.7.2 Insulated conductors |
49 | 4.7.3 Winding impregnation 4.7.4 Conductor dimensions 4.7.5 Sensing elements |
50 | 4.8 Temperature limitations 4.8.1 General |
51 | 4.8.2 Conductors 4.8.3 Insulated windings |
52 | 4.9 Wiring internal to equipment |
53 | 4.10 Degrees of protection provided by enclosures |
54 | 4.11 Fasteners 5.1 General 5.2 Electrical machines 5.2.1 General |
55 | 5.2.2 Degrees of protection provided by electrical machines, Level of Protection āebā 5.2.3 Degrees of protection provided by electrical machines, Level of Protection āecā 5.2.4 Connection facilities for external conductors |
56 | 5.2.5 Internal fans 5.2.6 Minimum air gap |
57 | 5.2.7 Rotating electrical machines with cage rotors |
59 | 5.2.8 Limiting temperature |
62 | 5.2.9 Machines with permanent magnet rotors |
63 | 5.2.10 Stator winding insulation system 5.2.11 Supplemental winding requirements Level of Protection āebā 5.2.12 Bearing seals and shaft seals |
64 | 5.2.13 Neutral point connections 5.3 Luminaires, hand lights, or caplights 5.3.1 General |
65 | 5.3.2 Light source |
66 | 5.3.3 Minimum distance between lamp and protective cover 5.3.4 Electrical spacings |
67 | 5.3.5 Lampholders and lamp caps |
70 | 5.3.6 Auxiliaries for Luminaires in Level of Protection āecā |
71 | 5.3.7 Surface temperatures |
72 | 5.3.8 Limiting temperatures 5.3.9 Luminaires for tubular fluorescent bi-pin lamps |
73 | 5.3.10 Tests for resistance to impact 5.4 Analog measuring instruments and instrument transformers 5.4.1 General |
74 | 5.4.2 Limiting temperature 5.4.3 Short-circuit currents 5.4.4 Short time thermal current 5.4.5 Measuring instruments supplied by current transformers 5.4.6 Moving coils 5.4.7 External secondary circuits |
75 | 5.5 Transformers other than instrument transformers 5.6 Supplementary requirements for equipment incorporating cells and batteries 5.6.1 Type of cells and batteries |
76 | 5.6.2 Requirements for cells and batteries ā¤25 Ah |
79 | 5.6.3 Requirements for valve-regulated or vented cells or batteries >25 Ah |
82 | 5.6.4 Charging of cells and batteries |
83 | 5.7 General purpose connection and junction boxes 5.8 Resistance heating equipment (other than trace heating systems) 5.8.1 General |
84 | 5.8.2 Heating resistors 5.8.3 Temperature coefficient 5.8.4 Insulating material 5.8.5 Cold-start current 5.8.6 Electrical safety device |
85 | 5.8.7 Electrically conductive covering 5.8.8 Exclusion of explosive atmosphere 5.8.9 Conductor cross-section 5.8.10 Limiting temperature |
86 | 5.8.11 Safety device |
87 | 5.9 Supplementary requirements for fuses 5.9.1 General 5.9.2 Temperature class of equipment 5.9.3 Fuse mounting 5.9.4 Fuse enclosures 5.9.5 Replacement fuse identification 5.10 Other electrical equipment |
88 | 6.1 Dielectric strength |
89 | 6.2 Rotating electrical machines 6.2.1 Determination of starting current ratio IA/ IN and the time tE 6.2.2 Mounting of machine for test 6.2.3 Additional tests for machines |
90 | 6.2.4 Overspeed test of cemented magnets |
91 | 6.3 Luminaires 6.3.1 Battery operated luminaires 6.3.2 Impact and drop tests 6.3.3 Mechanical tests for screw lampholders other than E10 |
92 | 6.3.4 Abnormal operation of luminaires |
94 | 6.3.5 Sulphur dioxide test for Level of Protection āebā for the connection of bi-pin lamp caps to lampholders 6.3.6 Vibration test for Level of Protection āebā for luminaires with bi-pin lamps |
95 | 6.3.7 Test for wiring of luminaires subject to high-voltage impulses from ignitors |
96 | 6.3.8 Tests for electronic starters for tubular fluorescent lamps and for ignitors in Level of Protection āecā for discharge lamps |
97 | 6.3.9 Test for starter holders for luminaires in Level of Protection āecā 6.4 Measuring instruments and instrument transformers |
98 | 6.5 Transformers other than instrument transformers 6.6 Verification and tests for cells and batteries of Level of Protection āebā 6.6.1 General 6.6.2 Insulation resistance 6.6.3 Mechanical shock test |
99 | 6.6.4 Test for ventilation of Level of Protection āebā battery container |
100 | 6.7 Verification and tests for cells and batteries of Level of Protection āecā 6.7.1 General 6.7.2 Insulation resistance 6.7.3 Mechanical shock test 6.7.4 Test for ventilation of Level of Protection āecā battery container |
101 | 6.8 General purpose connection and junction boxes 6.8.1 General 6.8.2 Maximum dissipated power method 6.8.3 Defined arrangement method 6.9 Resistance heating equipment |
102 | 6.10 Terminal insulating material tests |
103 | 7.1 Dielectric tests |
104 | 7.2 Dielectric tests for batteries 7.3 Inter-turn overvoltage tests 8.1 General 8.2 Terminals |
105 | 9.1 General marking |
106 | 9.2 Ex Component enclosures 9.3 Instructions for use 9.3.1 Battery operated equipment 9.3.2 Terminals |
107 | 9.3.3 Luminaires 9.3.4 Machines 9.4 Warning markings |