Shopping Cart

No products in the cart.

BS EN IEC 61158-4-24:2019

$215.11

Industrial communication networks. Fieldbus specifications – Data-link layer protocol specification. Type 24 elements

Published By Publication Date Number of Pages
BSI 2019 128
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

IEC 61158-4-24:2019 specifies procedures for the timely transfer of data and control information from one data-link user entity to a peer user entity, and among the data-link entities forming the distributed data-link service provider and the structure of the fieldbus DLPDUs used for the transfer of data and control information by the protocol of this standard, and their representation as physical interface data units. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision with the following technical changes: lt;br /gt;ā€¢patent declaration in the Introduction; lt;br /gt;ā€¢corrections on transmission sequence of fixed-width time slot type in 4.3.2; lt;br /gt;ā€¢technical extension for band sharing between I/O data exchange and message communication; lt;br /gt;ā€¢spelling and grammar

PDF Catalog

PDF Pages PDF Title
2 National foreword
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
7 CONTENTS
11 FOREWORD
13 INTRODUCTION
15 1 Scope
1.1 General
1.2 Specifications
1.3 Procedures
16 1.4 Applicability
1.5 Conformance
2 Normative references
17 3 Terms, definitions, symbols, abbreviations and conventions
3.1 Reference model terms and definitions
18 3.2 Service convention terms and definitions
3.3 Common terms and definitions
21 3.4 Symbols and abbreviations
22 3.5 Additional TypeĀ 24 symbols and abbreviations
3.6 Common Conventions
23 3.7 Additional Type 24 conventions
3.7.1 Primitive conventions
3.7.2 State machine conventions
Tables
TableĀ 1 ā€“ State transition descriptions
24 4 Overview of DL-protocol
4.1 Characteristic feature of the DL-protocol
TableĀ 2 ā€“ Description of state machine elements
TableĀ 3 ā€“ Conventions used in state machines
25 4.2 DL layer component
TableĀ 4 ā€“ Characteristic features of the fieldbus data-link protocol
26 4.2.1 Cyclic transmission control (CTC)
4.2.2 Send Receive Control (SRC)
4.2.3 DL-management
4.3 Timing sequence
4.3.1 Overview
4.3.2 Cyclic transmission mode
Figures
FigureĀ 1 ā€“ Data-link layer component
27 FigureĀ 2 ā€“ Timing chart of fixed-width time slot type cyclic communication
29 FigureĀ 3 ā€“ Timing chart of configurable time slot type cyclic communication
31 FigureĀ 4 ā€“ Schematic diagram of cyclic event occurrence
34 4.3.3 Acyclic transmission mode
FigureĀ 5 ā€“ Timing relationship between cyclic transmission and data processing
FigureĀ 6 ā€“ Timing chart example of acyclic communication
35 4.4 Service assumed from the PhL
4.4.1 General requirement
4.4.2 DL_Symbols
4.4.3 Assumed primitives of the PhS
4.5 Local parameters, variables, counters, timers
4.5.1 Overview
36 4.5.2 Variables, parameters, counters and timers to support DLE function
TableĀ 5 ā€“ List of the values of the variable Cyc_sel
37 TableĀ 6 ā€“ List of the values of the variable Tunit
38 TableĀ 7 ā€“ List of the values of the variable PDUType
39 TableĀ 8 ā€“ List of the values of the variable SlotType
40 5 DLPDU structure
5.1 Overview
5.1.1 Transfer syntax for bit sequences
41 5.1.2 Data type encodings
5.1.3 Frame format
5.2 Basic format DLPDU structure
5.2.1 General
TableĀ 9 ā€“ Transfer syntax for bit sequences
TableĀ 10 ā€“ Bit order
42 FigureĀ 7 ā€“ Basic format DLPDU structure
TableĀ 11 ā€“ Destination and Source address format
TableĀ 12 ā€“ Station address
43 TableĀ 13 ā€“ Extended address
TableĀ 14 ā€“ Message control field format (Information transfer format)
TableĀ 15 ā€“ Message control field format (Supervisory format)
44 TableĀ 16 ā€“ The list of Supervisory function bits
TableĀ 17 ā€“ Frame type and data length format
TableĀ 18 ā€“ The list of Frame type
45 5.2.2 Synchronous frame
5.2.3 Output data or Input data frame
TableĀ 19 ā€“ Data format of the Synchronous frame
TableĀ 20 ā€“ The field list of the Synchronous frame
TableĀ 21 ā€“ Data format of the Output data or the Input data frame
46 5.2.4 Delay measurement start frame
5.2.5 Delay measurement frame
TableĀ 22 ā€“ The field list of the Output data or the Input data frame
TableĀ 23 ā€“ Data format of Delay measurement start frame
TableĀ 24 ā€“ The field list of Delay measurement start frame
47 5.2.6 Message token frame
5.2.7 Status frame
TableĀ 25 ā€“ Data format of Delay measurement frame
TableĀ 26 ā€“ The field list of Delay measurement frame
TableĀ 27 ā€“ Data format of Status frame
48 5.2.8 Cycle Information frame
TableĀ 28 ā€“ The field list of Status frame
TableĀ 29 ā€“ The list of the DLE status
TableĀ 30 ā€“ The list of Repeater status
49 5.2.9 Message frame
TableĀ 31 ā€“ Data format of Delay measurement frame
TableĀ 32 ā€“ The field list of Cycle Information frame
TableĀ 33 ā€“ Data format of Message frame
50 5.3 Short format DLPDU structure
5.3.1 General
FigureĀ 8 ā€“ Short format DLPDU structure
TableĀ 34 ā€“ The field list of Message frame
51 TableĀ 35 ā€“ Range of Station address field
TableĀ 36 ā€“ Control field format (I/O data exchange format)
TableĀ 37 ā€“ Control field format (Message format)
52 5.3.2 Synchronous frame
TableĀ 38 ā€“ The field list of Message format
TableĀ 39 ā€“ Data format of the Synchronous frame
53 5.3.3 Output data or Input data frame
TableĀ 40 ā€“ The field list of the Synchronous frame
TableĀ 41 ā€“ Data format of the Output data frame
TableĀ 42 ā€“ The field list of the Output data frame
TableĀ 43 ā€“ Data format of the Input data frame
TableĀ 44 ā€“ The field list of the Input data frame
54 5.3.4 Message frame
6 DLE element procedure
6.1 Overview
6.2 Cyclic transmission control sublayer
6.2.1 General
6.2.2 DLS-user interface
TableĀ 45 ā€“ Primitives and parameters for the DLS-user interface issued by the DLS-user
55 6.2.3 Protocol machines in CTC
TableĀ 46 ā€“ Primitives and parameters for the DLS-user interface issued by the CTC
56 FigureĀ 9 ā€“ The state diagram of the C1 master for fixed-width time slot
57 TableĀ 47 ā€“ The state table of the C1 master for fixed-width time slot
63 FigureĀ 10 ā€“ The state diagram of the C2 master for fixed-width time slot
64 TableĀ 48 ā€“ The state table of the C2 master for fixed-width time slot
67 FigureĀ 11 ā€“ The state diagram of the slave for fixed-width time slot
68 TableĀ 49 ā€“ The state table of the slave for fixed-width time slot
70 FigureĀ 12 ā€“ The state diagram of the C1 master for configurable time slot
71 TableĀ 50 ā€“ The state table of the C1 master for configurable time slot
79 FigureĀ 13 ā€“ The state diagram of the C2 master for configurable time slot
80 TableĀ 51 ā€“ The state table of the C2 master for configurable time slot
82 FigureĀ 14 ā€“ The state diagram of slave for configurable time slot
83 TableĀ 52 ā€“ The state table of slave for configurable time slot
84 TableĀ 53 ā€“ The list of functions used by cyclic transmission machine
87 FigureĀ 15 ā€“ The state diagram of message initiator for basic format
TableĀ 54 ā€“ The state table of message initiator for basic format
91 FigureĀ 16 ā€“ The state diagram of message responder for basic format
TableĀ 55 ā€“ The state table of message responder for basic format
95 FigureĀ 17 ā€“ The state diagram of message initiator for short format
TableĀ 56 ā€“ The state table of message initiator for short format
99 FigureĀ 18 ā€“ The state diagram of message responder for short format
100 TableĀ 57 ā€“ The state table of message responder for short format
104 TableĀ 58 ā€“ List of functions used by the message segmentation machine
105 FigureĀ 19 ā€“ The state diagram of the acyclic transmission protocol machine
106 6.2.4 CTC-DLM interface
TableĀ 59 ā€“ The state table of the acyclic transmission protocol machine
TableĀ 60 ā€“ The list of functions used acyclic transmission protocol machine
107 6.3 Send Receive Control
6.3.1 General
TableĀ 61 ā€“ Primitives and parameters exchanged between CTC and DLM
TableĀ 62 ā€“ Error event primitive and parameters
108 6.3.2 SRC-CTC interface
TableĀ 63 ā€“ primitives and parameters for SRC-CTC interface
TableĀ 64 ā€“Ā Send frame primitive and parameters
109 6.3.3 Detailed specification of SRC
FigureĀ 20 ā€“ Internal architecture of one-port SRC
FigureĀ 21 ā€“ Internal architecture of multi-port SRC
TableĀ 65 ā€“Ā Receive frame primitives and parameters
110 FigureĀ 22 ā€“ Internal architecture of serializer
111 FigureĀ 23 ā€“ Internal architecture of deserializer
113 6.3.4 SRC-DLM interface
TableĀ 66 ā€“ Primitives and parameters exchanged between SRC and DLM
114 7 DL-management layer (DLM)
7.1 Overview
7.2 Primitive definitions
7.2.1 Primitives exchanged between DLMS-user and DLM
TableĀ 67 ā€“ Get value primitive and parameters
TableĀ 68 ā€“ Error event primitive and parameters
115 7.2.2 Parameters used with DLM primitives
7.3 DLM protocol machine
7.3.1 C1 master
TableĀ 69 ā€“ The list of primitives and parameters (DLMS-user source)
TableĀ 70 ā€“ The list of primitives and parameters (DLM source)
116 FigureĀ 24 ā€“ State diagram of the C1 master DLM
117 TableĀ 71 ā€“ State table of the C1 Master DLM
120 7.3.2 Slave and C2 master
121 FigureĀ 25 ā€“ State diagram of the Slave and the C2 master DLM
122 TableĀ 72 ā€“ State table of the Slave and the C2 master DLM
124 7.4 Functions
125 TableĀ 73 ā€“ The list of the functions used by DLM protocol machine
127 Bibliography
BS EN IEC 61158-4-24:2019