Shopping Cart

No products in the cart.

BS EN ISO 12631:2017

$198.66

Thermal performance of curtain walling. Calculation of thermal transmittance

Published By Publication Date Number of Pages
BSI 2017 62
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies a method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames.

The calculation includes:

  • different types of glazing, e.g. glass or plastic; single or multiple glazing; with or without low emissivity coating; with cavities filled with air or other gases;

  • frames (of any material) with or without thermal breaks;

  • different types of opaque panels clad with metal, glass, ceramics or any other material.

Thermal bridge effects at the rebate or connection between the glazed area, the frame area and the panel area are included in the calculation.

The calculation does not include:

  • effects of solar radiation;

  • heat transfer caused by air leakage;

  • calculation of condensation;

  • effect of shutters;

  • additional heat transfer at the corners and edges of the curtain walling;

  • connections to the main building structure nor through fixing lugs;

  • curtain wall systems with integrated heating.

NOTE Table 1 in the Introduction shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

PDF Catalog

PDF Pages PDF Title
2 National foreword
9 Foreword
10 Introduction
15 1 Scope
2 Normative references
16 3 Terms and definitions
17 4 Symbols and subscripts
4.1 Symbols
4.2 Subscripts
4.3 Superscripts
5 Description of the methods
5.1 Output of the method
18 5.2 General description
5.3 Geometrical characteristics
5.3.1 Main principles
20 5.3.2 Internal depth
21 5.3.3 Boundaries of curtain wall structures
24 5.3.4 Cut-off planes and partitioning of thermal zones
6 Methodologies for the calculation of curtain wall transmittance
26 7 Single assessment method
7.1 Output data
7.2 Calculation time intervals
7.3 Input data
7.3.1 Geometrical characteristics
30 7.3.2 Thermal characteristics
32 7.4 Calculation procedure
7.4.1 Applicable time interval
7.4.2 Calculation of thermal transmittance
33 8 Component assessment method
8.1 Output data
8.2 Calculation time intervals
8.3 Input data
8.3.1 Geometrical characteristics
37 8.3.2 Thermal characteristics
40 8.4 Calculation procedure
8.4.1 Applicable time interval
8.4.2 Calculation of thermal transmittance
41 9 Report
9.1 Contents of report
42 9.2 Drawings
9.2.1 Section drawings
9.2.2 Overview drawing of the whole curtain wall element
9.3 Values used in the calculation
9.4 Presentation of results
43 Annex A (normative) Input and method selection data sheet — Template
45 Annex B (informative) Input and method selection data sheet — default choices
47 Annex C (normative) Regional references in line with ISO Global Relevance Policy
48 Annex D (normative) Linear thermal transmittance of junctions
55 Annex E (normative) A method for calculating the thermal effect of screws using a 2D numerical method and the procedures specified in ISO 10077-2
58 Annex F (normative) Ventilated and unventilated air spaces
61 Bibliography
BS EN ISO 12631:2017
$198.66