BS ISO 12176-2:2008+A1:2021
$142.49
Plastics pipes and fittings. Equipment for fusion jointing polyethylene systems – Electrofusion
Published By | Publication Date | Number of Pages |
BSI | 2021 | 28 |
This part of ISO 12176 specifies performance requirements for electrofusion control units for use with polyethylene (PE) electrofusion fittings for the supply of gaseous fuels or for the conveyance of water for human consumption, including raw water prior to treatment, and for the conveyance of water for general purpose or other fluids.
The control units are divided into three input voltage classes: SVLV [safety, very low voltage (up to 50 V)], LV [low voltage (50 V to 250 V)] and HV [higher voltage (250 V to 400 V)].
This part of ISO 12176 is applicable to electrofusion control units designed for use in the construction of joints between PE pipes and fittings conforming to International Standards for the supply of gaseous fuels or for the conveyance of water, where the normal operating temperature of the control unit is in the range −10 °C to +40 °C. If temperatures outside this range are expected, suitable operating limits are subject to agreement between manufacturer and purchaser.
This part of ISO 12176 is applicable to control units with current or voltage control for fitting systems based on standard resistance wire heating technology.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
7 | Foreword |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
11 | 4 Designation of the different types of control unit 5 Construction requirements 5.1 General |
12 | 5.2 Electrical safety 5.3 Cables 5.3.1 General 5.3.2 Input cable 5.3.3 Output cable 5.4 Cable connectors |
13 | 5.5 Operator controls 5.6 Displays 5.7 Temperature-sensing element for fusion energy compensation 5.8 Input data decoder 5.9 Data retrieval and transmission 5.9.1 General 5.9.2 Memory |
14 | 5.9.3 Interface 5.9.4 Data protection 5.10 Transformers 5.11 Duty cycle 6 Operating procedures 6.1 Supply checks 6.2 Fusion data input 6.2.1 Manual input |
15 | 6.2.2 Automatic input 6.3 Data validation 6.3.1 General 6.3.2 Data validation by the control unit 6.3.3 Data validation by the operator 6.4 Fusion cycle 6.4.1 Fusion time and energy 6.4.2 Incidents during fusion cycle |
16 | 6.4.3 Optional programs and equipment 7 Operating requirements 7.1 General 7.2 Power supply 7.3 Coil resistance measurement/electrical continuity check 7.4 Energy output 7.4.1 Energy control |
17 | 7.4.2 Cycle time 7.4.3 Energy control 7.4.4 Power overload 7.5 Safety devices 7.5.1 General 7.5.2 Obligatory safety devices |
18 | 7.5.3 Optional safety devices 7.6 Counter 7.7 Endurance 8 Mechanical performance 8.1 Shock resistance test |
19 | 8.2 Vibration test 9 Technical file 10 Marking |
20 | Annex A (normative) Designation scheme |
23 | Annex B (informative) Duty cycle |
24 | Annex C (normative) Shock resistance test |
25 | Annex D (normative) Vibration test |
26 | Bibliography |