Shopping Cart

No products in the cart.

ISO 9855:1993

$19.50

Ambient air — Determination of the particulate lead content of aerosols collected on filters — Atomic absorption spectrometric method

Published By Publication Date Number of Pages
ISO 1993-10 10
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The principle of the method specified is based on digesting with acid the particulate material collected on a filter, solubilizing any lead present und analysing the sample solution by atomic absorption spectrometry (AAS). The method is applicable to ambient air samples with particulate lead contents, such that the amount of deposited particulate lead collected on the filter is greater than 1 µg if flame AAS is used. Final determination by graphite furnace AAS allows measurement of quantities of less than 1 µg, but is only applicable after experimental validation of detection limits.

ISO 9855:1993