NFPA 1986 2017
$80.71
NFPA 1986: Standard on Respiratory Protection Equipment for Tactical and Technical Operations
Published By | Publication Date | Number of Pages |
NFPA | 2017 | 67 |
Choose, use, and maintain SCBA and SARs to help keep law enforcement and tactical operations response personnel safe with new NFPA 1986: Respiratory Protection Equipment for Tactical and Technical Operations Vital for anyone responsible for the safety of personnel engaged in law enforcement, tactical operations, confined space rescue, disaster response, or similar challenges, NFPA 1986: Standard on Respiratory Protection Equipment for Tactical and Technical Operations specifies the minimum requirements for the design, performance, testing, and certification of new compressed breathing air open-circuit self-contained breathing apparatus (SCBA) and compressed breathing air combination open-circuit self-contained breathing apparatus, and supplied air respirators (SCBA/SARs). Requirements also cover the replacement parts, components, and accessories for these respirators. Detailed chapters address: Certification and recertification, manufacturers’ quality assurance, safety alerts, and recall systems Labeling and information Design requirements, including optional HUD design requirements and optional Rapid Intervention Crew/Company Universal Air Connection (RIC UAC) design requirements Performance requirements; airflow, environmental temperature, vibration resistance, corrosion resistance, etc. Test methods Annexes with explanatory material and a Surrogate Cylinder Preparation Procedure This first-edition Standard is essential for law enforcement and tactical operations, as well as equipment manufacturers, certifying authorities, purchasers, and AHJs. Provide respiratory protection of emergency services personnel in law enforcement, tactical operations, confined space rescue, and other emergency response in atmospheres that are immediately dangerous to life or health (IDLH) with NFPA 1986
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. |
10 | 1.4 Units. Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. 2.3 Other Publications. 2.4 References for Extracts in Mandatory Sections. (Reserved) Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. |
11 | 3.3 General Definitions. |
13 | Chapter 4 Certification 4.1 General. 4.2 Certification Program. |
14 | 4.3 Inspections and Testing. |
16 | 4.4 Recertification. 4.5 Manufacturers’ Quality Assurance Programs |
17 | 4.6 Hazards Involving Compliant Product. 4.7 Manufacturers’ Investigations of Complaints and Returns. 4.8 Manufacturers’ Safety Alert and Product Recall Systems. |
18 | Chapter 5 Labeling and Information 5.1 Product Label Requirements. 5.2 User Information. |
19 | Chapter 6 Design Requirements 6.1 General Design Requirements. 6.2 End-of-Service-Time Indicator (EOSTI) Design Requirements. 6.3 Optional HUD Design Requirements. |
20 | 6.4 Optional Rapid Intervention Crew/Company Universal Air Connection (RIC UAC) Design Requirements. |
21 | 6.5 Power Source Design Requirements. |
22 | 6.6 Optional Emergency Breathing Safety System (EBSS) Design Requirements. 6.7 Accessories Design Requirements. Chapter 7 Performance Requirements 7.1 Airflow Performance. 7.2 Environmental Temperature Performance. |
23 | 7.3 Vibration Resistance Performance. 7.4 Corrosion Resistance Performance. 7.5 Particulate Resistance Performance. 7.6 Facepiece Lens Abrasion Resistance Performance. 7.7 Nonelectronic Communications Performance Requirements. |
24 | 7.8 Flame Resistance Performance. 7.9 Carbon Dioxide (CO2) Content Performance. 7.10 EOSTI Alarm Recognition. 7.11 Additional SCBA HUD Performance. 7.12 RIC UAC Performance Requirements. 7.13 Breathing Air Cylinder Performance Requirements. 7.14 Supplementary Voice Communications System Performance Requirements. 7.15 Immersion Leakage Performance Requirements. 7.16 Low Power Capacity. 7.17 Emergency Breathing Safety System Cold Temperature Performance Requirements. |
25 | Chapter 8 Test Methods 8.1 Airflow Performance Test. |
28 | 8.2 Environmental Temperature Tests. |
31 | 8.3 Vibration Test. |
33 | 8.4 Accelerated Corrosion Test. 8.5 Particulate Test. |
34 | 8.6 Facepiece Lens Abrasion Test. |
37 | 8.7 Nonelectronic Communications Test. |
39 | 8.8 Flame Test. |
44 | 8.9 Facepiece Carbon Dioxide Content Test. 8.10 EOSTI Recognition Test. |
45 | 8.11 HUD Wiring Connection Strength Test. 8.12 HUD Low Power Source Alert Signal Test. |
46 | 8.13 HUD Visibility Tests. 8.14 Light Test. |
47 | 8.15 HUD Disabling Glare Test. 8.16 Cylinder Refill Breathing Performance Test. |
48 | 8.17 RIC UAC System Fill Rate Test. 8.18 Breathing Air Cylinder and Valve Assembly Retention Test. |
49 | 8.19 Immersion Leakage Test. 8.20 Cylinder Connections and Accessibility Test. |
50 | 8.21 Supplementary Voice Communications System Performance Test. |
52 | 8.22 Low Power Capacity Test. 8.23 Emergency Breathing Safety System (EBSS) Cold Temperature Performance Test. |
53 | Annex A Explanatory Material |
57 | Annex B Surrogate Cylinder Preparation Procedure |
58 | Annex C Informational References |