Shopping Cart

No products in the cart.

SMACNA HVACDuctConstructionStandards 2005 03E

$133.79

HVAC Duct Construction Standards – Metal and Flexible, 3rd Edition

Published By Publication Date Number of Pages
SMACNA 2005 396
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The third edition of the HVAC Duct Construction Standards – Metal and Flexible is intended primarily for commercial and institutional duct construction. The standard contains tables and details for constructing ductwork for ½” to 10” wg positive and negative pressures. This edition improves upon the second edition with expanded pressure class tables, separate tables for TDC/TDF construction and expanded tables for round duct construction including 6” wg positive and negative pressure and sizes up to 96”. New in this edition is an engineering and design chapter to provide additional information to design professionals, double-wall construction details, new casing construction details and additional accessory items. The standard is applicable for construction using uncoated steel, galvanized and stainless steels and a limited range of aluminum ducts. This standard has been adopted in the ICC International Mechanical Code. Includes soft metrics.

PDF Catalog

PDF Pages PDF Title
5 FOREWORD
6 HVAC DUCT CONSTRUCTION TASK FORCE
7 NOTICE TO USERS OF THIS PUBLICATION
9 MODEL PROJECT SPECIFICATION
10 LIST OF MAJOR CHANGES FROM THE SECOND EDITION
13 TABLE OF CONTENTS
21 CHAPTER 1 ENGINEERING AND DESIGN
1.1 INTRODUCTION
1.2 INFORMATION REQUIRED FOR DUCT CONSTRUCTION
1.3 MODEL SPECIFICATIONS
31 1.4 DUCT SEALING
Table 1-1 Standard Duct Sealing Requirements
33 1.5 INTRODUCTION TO BASIC CONSTRUCTION
36 FIGURE 1-1 DUCT PRESSURE CLASSIFICATION
37 Table 1-2 Pressure Classification for Ductwork
38 1.6 DEPENDENT VARIABLES
Table 1-3 Static Pressure
39 FIGURE 1-2 DEPENDENT VARIABLES
40 FIGURE 1-3 SYMBOLS FOR HVAC SYSTEMS (I-P)
41 FIGURE 1-3M SYMBOLS FOR HVAC SYSTEMS (SI)
47 CHAPTER 2 RECTANGULAR DUCT CONSTRUCTION
2.1 INTRODUCTION TO THE RECTANGULAR DUCT CONSTRUCTION SCHEDULES
50 2.2 RECTANGULAR DUCT REINFORCEMENT
52 FIGURE 2-1 RECTANGULAR DUCT/TRANSVERSE JOINTS
53 FIGURE 2-1 RECTANGULAR DUCT/TRANSVERSE JOINTS (CONTINUED)
54 FIGURE 2-1 RECTANGULAR DUCT/TRANSVERSE JOINTS (CONTINUED)
55 FIGURE 2-1 RECTANGULAR DUCT/TRANSVERSE JOINTS (CONTINUED)
56 FIGURE 2-2 RECTANGULAR DUCT/LONGITUDINAL SEAMS
57 2.3 LONGITUDINAL SEAMS FOR RECTANGULAR DUCT
58 FIGURE 2-3 RECTANGULAR DUCT EXTERNAL REINFORCEMENTS
60 Table 2-1 Rectangular Duct Reinforcement
61 Table 2-1M Rectangular Duct Reinforcement
62 Table 2-2 Rectangular Duct Reinforcement
63 Table 2-2M Rectangular Duct Reinforcement
64 Table 2-3 Rectangular Duct Reinforcement
65 Table 2-3M Rectangular Duct Reinforcement
66 Table 2-4 Rectangular Duct Reinforcement
67 Table 2-4M Rectangular Duct Reinforcement
68 Table 2-5 Rectangular Duct Reinforcement
69 Table 2-5M Rectangular Duct Reinforcement
70 Table 2-6 Rectangular Duct Reinforcement
71 Table 2-6M Rectangular Duct Reinforcement
72 Table 2-7 Rectangular Duct Reinforcement
73 Table 2-7M Rectangular Duct Reinforcement
74 Table 2-8 4 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
75 Table 2-8M 1.20 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
76 Table 2-9 4 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
77 Table 2-9M 1.20 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
78 Table 2-10 4 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
79 Table 2-10M 1.20 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
80 Table 2-11 4 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
81 Table 2-11M 1.20 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
82 Table 2-12 4 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
83 Table 2-12M 1.20 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
84 Table 2-13 4 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
85 Table 2-13M 1.20 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
86 Table 2-14 4 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
87 Table 2-14M 1.20 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
88 Table 2-15 5 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
89 Table 2-15M 1.50 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
90 Table 2-16 5 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
91 Table 2-16M 1.50 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
92 Table 2-17 5 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
93 Table 2-17M 1.50 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
94 Table 2-18 5 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
95 Table 2-18M 1.50 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
96 Table 2-19 5 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
97 Table 2-19M 1.50 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
98 Table 2-20 5 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
99 Table 2-20M 1.20 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
100 Table 2-21 5 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
101 Table 2-21M 1.50 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
102 Table 2-22 6 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
103 Table 2-22M 1.80 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
104 Table 2-23 6 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
105 Table 2-23M 1.80 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
106 Table 2-24 6 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
107 Table 2-24M 1.80 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
108 Table 2-25 6 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
109 Table 2-25M 1.80 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
110 Table 2-26 6 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
111 Table 2-26M 1.80 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
112 Table 2-27 6 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
113 Table 2-27M 1.80 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
114 Table 2-28 6 ft Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
115 Table 2-28M 1.80 m Coil/Sheet Stock/T25a/T25b (TDC/TDF) Duct Reinforcement
116 Table 2-29 Intermediate Reinforcement
117 Table 2-29M Intermediate Reinforcement
118 Table 2-30 Framing Channel
Table 2-30M Framing Channel
FIGURE 2-4 CHANNEL (STRUT) USED AS DUCT REINFORCEMENT
119 2.4 TRANSVERSE JOINTS FOR RECTANGULAR DUCT
120 Table 2-31 Transverse Joint Reinforcement
121 Table 2-31M Transverse Joint Reinforcement
122 Table 2-32 Transverse Joint Reinforcement
123 Table 2-32M Transverse Joint Reinforcement
124 Table 2-33 Transverse Joint Reinforcement
125 Table 2-33M Transverse Joint Reinforcement
126 2.5 TIE ROD INSTALLATIONS
127 2.6 COMMENTARY
128 FIGURE 2-5 TIE ROD ATTACHMENTS
129 FIGURE 2-6 TIE ROD ATTACHMENTS
130 Table 2-34 Internal Tie Rod Design Load in Pounds
131 Table 2-34M Internal Tie Rod Design Load in Kilograms
132 Table 2-35 Internal Tie Rod Size (+) Pressure
133 Table 2-35M Internal Tie Rod Size (+) Pressure
134 Table 2-36 Internal Tie Rod Size (-) Pressure
Table 2-36M Internal Tie Rod Size (-) Pressure
135 Table 2-37 Internal RC Conduit Size (-) Pressure
136 Table 2-37M Internal RC Conduit Size (-) Pressure
137 Table 2-38 Internal EMT Conduit Size (-) Pressure
138 Table 2-38M Internal EMT Conduit Size (-) Pressure
139 Table 2-39 Steel Pipe Size (-) Pressure
140 Table 2-39M Steel Pipe Size (-) Pressure
141 Table 2-40 Allowable Load for Angles as Columns with Maximum Unbraced Length L
142 Table 2-40M Allowable Load for Angles as Columns with Maximum Unbraced Length L
143 2.7 MIDPANEL TIE ROD APPLICATIONS
2.8 MIDPANEL TIE ROD (MPT) USE GUIDE
144 2.9 MIDPANEL TIE ROD SELECTIONS
146 Table 2-41 Midpanel Tie Rod (MPT) Schedule (RS)
147 Table 2-41M Midpanel Tie Rod (MPT) Schedule (RS)
148 Table 2-42 Internal Midpanel Tie Rod (MPT) Size (Dia.)
Table 2-42M Internal Midpanel Tie Rod (MPT) Size (Dia.)
149 Table 2-43 Internal Midpanel Tie Rod (MPT) Size (Dia.)
Table 2-43M Internal Midpanel Tie Rod (MPT) Size (Dia.)
150 Table 2-44 Internal Midpanel Tie Rod (MPT) Size (Dia.)
Table 2-44M Internal Midpanel Tie Rod (MPT) Size (Dia.)
151 Table 2-45 Internal Midpanel Tie Rod (MPT) Size (Dia.)
Table 2-45M Internal Midpanel Tie Rod (MPT) Size (Dia.)
152 Table 2-46 Midpanel Tie Rod (MPT) Design Load in Pounds
153 Table 2-46M Midpanel Tie Rod (MPT) Design Load in Kilograms
154 Table 2-47 Unreinforced Duct (Wall Thickness)
155 Table 2-47M Unreinforced Duct (Wall Thickness)
156 Table 2-48 T-1 Flat Drive Accepted as Reinforcement
Table 2-48M T-1 Flat Drive Accepted as Reinforcement
157 FIGURE 2-7 INSIDE STANDING SEAM – LONGITUDINAL – 2 IN. WG (500 Pa) MAXIMUM
158 FIGURE 2-8 UNREINFORCED DUCT
159 FIGURE 2-9 CROSSBROKEN AND BEADED DUCT
160 FIGURE 2-10 DUCT REINFORCED ON TWO SIDES
161 FIGURE 2-11 DUCT REINFORCED ON ALL SIDES
162 FIGURE 2-12 REINFORCEMENT ATTACHMENT
163 Table 2-49 Duct Over 120 in. (3000 mm) Duct Construction
FIGURE 2-13 DUCT OVER 120 IN. (3000 MM) WIDE
164 FIGURE 2-14 CORNER CLOSURES – SLIPS AND DRIVES
165 FIGURE 2-15 CORNER CLOSURES – FLANGES
166 FIGURE 2-16 CORNER CLOSURES – FLANGES
167 FIGURE 2-17 CORNER CLOSURES – FLANGES
168 FIGURE 2-18 CORNER CLOSURES
169 2.10 COMMENTARY ON ALUMINUM DUCT
170 Table 2-50 Thickness Adjustments
Table 2-51 Dimension Adjustments
Table 2-52 Reinforcements
175 CHAPTER 3 ROUND, OVAL AND FLEXIBLE DUCT
3.1 ROUND DUCT CONSTRUCTION STANDARDS
Table 3-1 Mitered Elbows
176 3.2 COMMENTARY
177 FIGURE 3-1 ROUND DUCT TRANSVERSE JOINTS
178 FIGURE 3-1 ROUND DUCT TRANSVERSE JOINTS (CONTINUED)
179 FIGURE 3-2 ROUND DUCT LONGITUDINAL SEAMS
180 Table 3-2 Angle Ring Size
Table 3-3 Ring Attachment Schedule
Table 3-4 Companion Flange Joints Used As Reinforcement
FIGURE 3-3 ROUND DUCT REINFORCEMENT
181 Table 3-2M Angle Ring Size
Table 3-3M Ring Attachment Schedule
Table 3-4M Companion Flange Joints Used As Reinforcement
FIGURE 3-3M ROUND DUCT REINFORCEMENT
182 Table 3-5 Round Duct Gage Unreinforced Positive Pressure To 10 in. wg
183 Table 3-5M Round Duct Gage Unreinforced Positive Pressure To 2500 Pa
184 Table 3-6 Min. Required Gage for Longitudinal Seam Duct Under Neg. Pressure
185 Table 3-6M Min. Required Gage for Longitudinal Seam Duct Under Neg. Pressure
186 Table 3-7 Min. Required Gage for Longitudinal Seam Duct Under Neg. Pressure
187 Table 3-7M Min. Required Gage for Longitudinal Seam Duct Under Neg. Pressure
188 Table 3-8 Min. Required Gage for Longitudinal Seam Duct Under Neg. Pressure
189 Table 3-8M Min. Required Gage for Longitudinal Seam Duct Under Neg. Pressure
190 Table 3-9 Min. Required Gage for Longitudinal Seam Duct Under Neg. Pressure
191 Table 3-9M Min. Required Gage for Longitudinal Seam Duct Under Neg. Pressure
192 Table 3-10 Min. Required Gage for Spiral Seam Duct Under Neg. Pressure
193 Table 3-10M Min. Required Gage for Spiral Seam Duct Under Neg. Pressure
194 Table 3-11 Min. Required Gage for Spiral Seam Duct Under Neg. Pressure
195 Table 3-11M Min. Required Gage for Spiral Seam Duct Under Neg. Pressure
196 Table 3-12 Min. Required Gage for Spiral Seam Duct Under Neg. Pressure
197 Table 3-12M Min. Required Gage for Spiral Seam Duct Under Neg. Pressure
198 Table 3-13 Min. Required Gage for Spiral Seam Duct Under Neg. Pressure
199 Table 3-13M Min. Required Gage for Spiral Seam Duct Under Neg. Pressure
200 Table 3-14 Aluminum Round Duct Gage Schedule
Table 3-14M Aluminum Round Duct Gage Schedule
201 3.3 FLAT OVAL DUCT CONSTRUCTION STANDARDS
3.4 COMMENTARY
202 Table 3-15 Flat Oval Duct Gage Positive Pressure To 10 in. wg
Table 3-15M Flat Oval Duct Gage Positive Pressure To 2500 Pa
203 FIGURE 3-4 ROUND DUCT ELBOWS
204 FIGURE 3-5 90 TEES AND LATERALS
205 FIGURE 3-6 CONICAL TEES
206 FIGURE 3-7 FLAT OVAL DUCTS
207 3.5 FLEXIBLE AIR DUCT INSTALLATION STANDARDS
3.6 SPECIFICATION FOR JOINING AND ATTACHING FLEXIBLE DUCT
3.7 SPECIFICATION FOR SUPPORTING FLEXIBLE DUCT
209 FIGURE 3-8 TYPES OF FLEXIBLE DUCT
210 FIGURE 3-9 TYPICAL ACCESSORIES
211 FIGURE 3-10 FLEXIBLE DUCT SUPPORTS
212 FIGURE 3-11 FLEXIBLE DUCT SUPPORTS
213 3.8 COMMENTARY
217 CHAPTER 4 FITTINGS AND OTHER CONSTRUCTION
4.1 REQUIREMENTS
218 FIGURE 4-1 TYPICAL SUPPLY OR RETURN DUCT
219 FIGURE 4-2 RECTANGULAR ELBOWS
220 FIGURE 4-2 RECTANGULAR ELBOWS (CONTINUED)
221 FIGURE 4-3 VANES AND VANE RUNNERS
222 FIGURE 4-4 VANE SUPPORT IN ELBOWS
223 FIGURE 4-5 DIVIDED FLOW BRANCHES
224 FIGURE 4-6 BRANCH CONNECTION
225 FIGURE 4-7 OFFSETS AND TRANSITIONS
226 FIGURE 4-8 OBSTRUCTIONS
227 CHART 4-1 NUMBER OF SHORT RADIUS VANES1
228 CHART 4-1M NUMBER OF SHORT RADIUS VANES2
229 FIGURE 4-9 CONSTRUCTION OF SHORT RADIUS VANES3
233 CHAPTER 5 HANGERS AND SUPPORTS
5.1 HANGING AND SUPPORTING SYSTEMS
5.2 COMMENTARY
235 FIGURE 5-1 HANGER ATTACHMENTS TO STRUCTURES
236 FIGURE 5-2 UPPER ATTACHMENT DEVICES – TYPICAL
237 FIGURE 5-3 ALTERNATIVE JOIST ATTACHMENTS
238 FIGURE 5-4 UPPER ATTACHMENTS – TYPICAL
239 Table 5-1 Rectangular Duct Hangers Minimum Size
240 Table 5-1M Rectangular Duct Hangers Minimum Size
241 Table 5-2 Minimum Hanger Sizes for Round Duct
242 FIGURE 5-5 LOWER HANGER ATTACHMENTS
243 Table 5-3 Allowable Loads in Pounds for Trapeze Bars
244 Table 5-3M Allowable Loads in Kilograms for Trapeze Bars
245 Table 5-4 Channel (Strut) Used as Trapeze
246 FIGURE 5-6 TRAPEZE LOAD DIAGRAM
247 FIGURE 5-7 LARGE DUCT SUPPORT
248 FIGURE 5-8 RISER SUPPORTS – FROM FLOOR
249 FIGURE 5-8M RISER SUPPORT – FROM FLOOR
250 FIGURE 5-9 SUPPORTS FROM WALL
251 FIGURE 5-9M SUPPORT FROM WALL
252 FIGURE 5-10 RISER SUPPORT – FROM FLOOR
253 FIGURE 5-11 TYPICAL HVAC UNIT SUSPENSION
257 CHAPTER 6 EXTERIOR COMPONENTS
6.1 INTRODUCTION
258 FIGURE 6-1 LOUVERS AND SCREENS
259 FIGURE 6-1M LOUVERS AND SCREENS
260 FIGURE 6-2 LOUVER FREE AREA CALCULATION
261 6.2 ROOFTOP EQUIPMENT INSTALLATION
6.3 COMMENTARY
262 FIGURE 6-3 ROOFTOP DUCT INSTALLATION
263 FIGURE 6-4 EQUIPMENT AND DUCT SUPPORT FLASHING
264 FIGURE 6-5 RECTANGULAR GOOSENECK
265 FIGURE 6-6 INTAKE OR EXHAUST VENTILATORS
266 FIGURE 6-7 LARGE INTAKE OR EXHAUST VENTILATORS
269 CHAPTER 7 ACCESSORIES
FIGURE 7-1 REMOTE HEATING AND COOLING COIL INSTALLATIONS
270 FIGURE 7-2 DUCT ACCESS DOORS AND PANELS
271 FIGURE 7-2M DUCT ACCESS DOORS AND PANELS
272 FIGURE 7-3 ACCESS DOORS – ROUND DUCT
273 7.1 VOLUME DAMPERS
7.2 NOTES FOR FIGURES 7-4 AND 7-5
7.3 COMMENTARY
274 FIGURE 7-4 VOLUME DAMPERS – SINGLE BLADE TYPE
275 FIGURE 7-5 MULTIBLADE VOLUME DAMPERS
276 FIGURE 7-6 GRILLE AND REGISTER CONNECTIONS
277 FIGURE 7-7 CEILING DIFFUSER BRANCH DUCTS
278 FIGURE 7-8 FLEXIBLE CONNECTIONS AT FAN
279 FIGURE 7-9 ALTERNATIVE FLEX CONNECTOR DETAILS
280 FIGURE 7-10 TYPICAL HVAC UNIT CONNECTIONS4
281 FIGURE 7-11 FLEXIBLE DUCT LINER INSTALLATION
282 7.4 INSTALLATION STANDARDS FOR RECTANGULAR DUCTS USING FLEXIBLE LINER
283 7.5 COMMENTARY
285 FIGURE 7-12 LINER FASTENERS
286 FIGURE 7-13 OPTIONAL HAT SECTION
287 FIGURE 7-14 DUCT LINER INTERRUPTION
291 CHAPTER 8 DOUBLE-WALL DUCT CONSTRUCTION
8.1 INSTALLATION STANDARDS COMMENTARY
292 FIGURE 8-1 FIRE DAMPER INSTALLATION IN DOUBLE-WALL DUCT
293 FIGURE 8-2 DOUBLE-WALL ROUND DUCT
294 FIGURE 8-3 RECTANGULAR DOUBLE-WALL DUCT
295 FIGURE 8-4 FLAT OVAL DOUBLE-WALL DUCT
296 FIGURE 8-5 DOUBLE-WALL DUCT FITTING
297 FIGURE 8-6 DOUBLE-WALL DUCT FITTING
298 FIGURE 8-7 DOUBLE-WALL DUCT SLEEVE
299 FIGURE 8-8 DOUBLE-WALL DUCT JOINT
300 FIGURE 8-9 DOUBLE-WALL DUCT TIE ROD INSTALLATION
301 FIGURE 8-10 DOUBLE-WALL DUCT ” VAN STONE JOINT
302 FIGURE 8-11 DOUBLE-WALL DUCT ” DAMPERS
303 FIGURE 8-12 DOUBLE-WALL DUCT WITH FLANGE CONNECTIONS
304 FIGURE 8-13 DOUBLE-WALL DUCT ” FLANGE CONNECTION
305 FIGURE 8-14 DOUBLE-WALL DUCT DETAILS
306 FIGURE 8-15 DOUBLE-WALL DUCT ACCESS DOORS
309 CHAPTER 9 EQUIPMENT AND CASINGS
9.1 CASING AND PLENUM CONSTRUCTION STANDARDS
310 FIGURE 9-1 BUILT-UP STANDING SEAM CASING
311 FIGURE 9-1M BUILT-UP STANDING SEAM CASING
312 FIGURE 9-2 STANDING SEAM CASINGS
313 FIGURE 9-3 ALTERNATE CASING CONSTRUCTION
314 Table 9-1 Alternate Casing Panels
315 Table 9-1 Alternate Casing Panels (Continued)
316 FIGURE 9-4 OVER 2 IN. WG (500 PA) CASING ARRANGEMENT
317 FIGURE 9-5 OVER 2 IN. WG PRESSURE APPARATUS CASING
318 FIGURE 9-5M OVER 500 PA PRESSURE APPARATUS CASING
319 FIGURE 9-6 INSIDE SEAM CASING – 6 IN. WG (1500 PA) MAX.
320 FIGURE 9-7 DOUBLE – WALL CASING
321 FIGURE 9-8 ALTERNATE CASING CONSTRUCTION USING TDC OR TDF FLANGES
322 FIGURE 9-9 ALTERNATE CASING CONSTRUCTION USING TDC OR TDF FLANGES
323 FIGURE 9-10 CORNER CLOSURES (USING TDC OR TDF)
324 FIGURE 9-11 DOUBLE-WALL CASING DETAILS
FIGURE 9-11M DOUBLE-WALL CASING DETAILS
325 FIGURE 9-11 DOUBLE-WALL CASING DETAILS (CONTINUED) TYPICAL ACCESS DOOR
FIGURE 9-11M DOUBLE-WALL CASING DETAILS (CONTINUED) TYPICAL ACCESS DOOR
326 FIGURE 9-12 CURB DETAIL
327 FIGURE 9-13 CASING ELIMINATORS AND DRAIN PANS
328 FIGURE 9-14 PIPE PENETRATIONS OF CASINGS
329 FIGURE 9-15 CASING ACCESS DOORS – 2 IN. WG (500 Pa)
330 Table 9-2 Plenum and Casing Access Doors ” 2 in. wg
Table 9-2M Plenum and Casing Access Doors ” 500 Pa
331 FIGURE 9-16 CASING ACCESS DOORS – 3-10 IN. WG (750-2500 Pa)
332 9.2 COMMENTARY
9.3 CASING ARRANGEMENT
337 CHAPTER 10 SPECIALTY SYSTEMS
FIGURE 10-1 LINEAR DIFFUSER PLENUM
338 10.1 HOODS
339 FIGURE 10-2 DISHWASHER VAPOR EXHAUST
340 10.2 UNDERGROUND DUCT CONSTRUCTION STANDARDS
341 FIGURE 10-3 TYPICAL UNDERSLAB DUCT
342 FIGURE 10-4 ANCHORS FOR DUCT ENCASEMENT
343 10.3 COMMENTARY
344 FIGURE 10-5 SECURITY DUCT BARRIER DETAIL
345 FIGURE 10-6 ALTERNATIVE SECURITY BARRIER DETAIL
349 CHAPTER 11 FUNCTIONAL CRITERIA
11.1 FUNCTIONAL CRITERIA FOR DUCTS
11.2 RECTANGULAR DUCTS
350 11.3 COMMENTARY
351 FIGURE 11-1 MODELS FOR FUNCTIONAL STANDARDS
352 FIGURE 11-2 TEST DUCT CONFIGURATION
353 FIGURE 11-3 DEFLECTION AND LEAKAGE MEASUREMENT
354 SMACNA DUCT PERFORMANCE TEST STANDARD NO. DPTS-2005
356 11.4 PROCEDURE FOR RATING DUCT CONSTRUCTION METHODS RELATIVE TO THE SMACNA CONSTRUCTION TABLES
357 11.5 NOTES ON SPECIMEN TESTING
358 11.6 SOUND AND VIBRATION
359 Table ‘A’ Minimum Threshold Velocities at Various Internal Static Pressures
361 FIGURE 11-4 TEST APPARATUS
362 FIGURE 11-4M TEST APPARATUS
363 Table ‘B’ Relative Vibration of Various Ducts
365 FIGURE 11-5 OSCILLOGRAPH TRACES
369 APPENDIX A
Galvanized Sheet Thickness Tolerances
370 Manufacturers Standard Gage-Thickness—Uncoated Steel
371 Stainless Steel Sheet Thickness
372 Aluminum Sheet Thickness—Alloy 3003-H14
373 Metric Conversion Chart
374 Duct Surface Area In Square Feet Per Linear Foot
375 Galvanized Sheet Weight
376 Galvanized Sheet Weight (Continued)
377 Approximate Weight – Round Duct in Pounds Per Linear Foot
378 Area And Circumferences of Circles
379 Angle, Bar and Channel Properties
380 A.1 CONTRACTOR’S ANALYSIS OF SHOP STANDARDS
A.2 NOTES
381 Sample Worksheet
382 SINGLE PATH AIR SYSTEMS
383 DUAL PATH AIR SYSTEMS
384 TERMINOLOGY FOR CENTRAL STATION APPARATUS
385 MOTOR ARRANGEMENTS
386 FAN ROTATION & DISCHARGE POSITIONS
387 TYPICAL BELT GUARDS
388 TYPICAL ISOLATION DEVICES
389 A.3 RADIATION PROTECTION AT WALL OPENINGS FOR DUCT OR PIPE
391 RADIATION PROTECTION AT WALL OPENINGS
392 RADIATION PROTECTION AT WALL OPENINGS
393 CONTRIBUTORS TO DOCUMENTS PRECEDING THE SECOND EDITION OF HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE
SMACNA HVACDuctConstructionStandards 2005 03E
$133.79