{"id":155562,"date":"2024-10-19T09:16:35","date_gmt":"2024-10-19T09:16:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/awwa-manual-m53-2016\/"},"modified":"2024-10-25T01:30:45","modified_gmt":"2024-10-25T01:30:45","slug":"awwa-manual-m53-2016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/awwa\/awwa-manual-m53-2016\/","title":{"rendered":"AWWA Manual M53 2016"},"content":{"rendered":"

Microfiltration and ultrafiltration have gained rapid acceptance as processes that provide a reliable and very high level of particle, turbidity, and microorganism removal. This manual contains information on low-pressure membranes in widely diverse applications, operations and system designs. It will help water operators, engineers, and management ensure the success of an installation. Chapters cover topics such as water quality, membrane science and theory, system concepts, MF and UF membrane manufacturers, applications, pilot testing, design concepts, operations, cost, residuals management and future trends. Unlike other publications on this topic that are intended to help facilitate regulatory compliance, this manual provides more detailed technical information and serves as a bridge between theoretical and real-world applications.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
3<\/td>\nCopyright <\/td>\n<\/tr>\n
4<\/td>\nContents <\/td>\n<\/tr>\n
8<\/td>\nFigures <\/td>\n<\/tr>\n
12<\/td>\nTables <\/td>\n<\/tr>\n
14<\/td>\nPreface <\/td>\n<\/tr>\n
16<\/td>\nAcknowledgments <\/td>\n<\/tr>\n
18<\/td>\nMetric Conversions <\/td>\n<\/tr>\n
20<\/td>\nChapter 1 Introduction to Low-Pressure Membrane Processes <\/td>\n<\/tr>\n
21<\/td>\nProcess Overview <\/td>\n<\/tr>\n
22<\/td>\nGrowth of Membrane Technology <\/td>\n<\/tr>\n
23<\/td>\nHistorical Overview of MF and UF <\/td>\n<\/tr>\n
25<\/td>\nCurrent Status
Future Trends <\/td>\n<\/tr>\n
26<\/td>\nReferences <\/td>\n<\/tr>\n
28<\/td>\nChapter 2 Water Quality
Water-Quality Factors <\/td>\n<\/tr>\n
30<\/td>\nParticle Removal <\/td>\n<\/tr>\n
31<\/td>\nMicrobial Control <\/td>\n<\/tr>\n
36<\/td>\nOrganic Control <\/td>\n<\/tr>\n
41<\/td>\nInorganic Control <\/td>\n<\/tr>\n
44<\/td>\nReferences <\/td>\n<\/tr>\n
52<\/td>\nChapter 3 Membrane Science and Theory
Water Permeation Across Clean MF\/UF Membranes <\/td>\n<\/tr>\n
57<\/td>\nReductions in Membrane Productivity <\/td>\n<\/tr>\n
67<\/td>\nSummary <\/td>\n<\/tr>\n
68<\/td>\nAcknowledgments
References <\/td>\n<\/tr>\n
72<\/td>\nChapter 4 System Concepts
Membrane Materials and Geometries <\/td>\n<\/tr>\n
76<\/td>\nProcess Design <\/td>\n<\/tr>\n
79<\/td>\nMF and UF Operation Concepts <\/td>\n<\/tr>\n
80<\/td>\nMembrane Backwashing and Pretreatment\/Posttreatment <\/td>\n<\/tr>\n
81<\/td>\nMembrane Pretreatment <\/td>\n<\/tr>\n
82<\/td>\nPosttreatment
Chemical Cleaning <\/td>\n<\/tr>\n
83<\/td>\nMembrane Integrity Testing <\/td>\n<\/tr>\n
89<\/td>\nReferences <\/td>\n<\/tr>\n
90<\/td>\nChapter 5 Pilot Testing of Membrane Systems <\/td>\n<\/tr>\n
92<\/td>\nPilot-Testing Protocol <\/td>\n<\/tr>\n
94<\/td>\nHydraulic Performance Evaluation <\/td>\n<\/tr>\n
100<\/td>\nSample Results and Organization of Pilot Study <\/td>\n<\/tr>\n
104<\/td>\nReferences <\/td>\n<\/tr>\n
106<\/td>\nChapter 6 Membrane System Design Concepts <\/td>\n<\/tr>\n
107<\/td>\nSite-Specific Issues <\/td>\n<\/tr>\n
112<\/td>\nMembrane-Specific Issues <\/td>\n<\/tr>\n
117<\/td>\nMembrane System Design Issues <\/td>\n<\/tr>\n
128<\/td>\nReferences <\/td>\n<\/tr>\n
130<\/td>\nChapter 7 Operations <\/td>\n<\/tr>\n
131<\/td>\nDifferences Between MF\/UF and Conventional Granular
\n Media Filtration <\/td>\n<\/tr>\n
132<\/td>\nHow To Control an MF\/UF Plant <\/td>\n<\/tr>\n
134<\/td>\nData Collection and Recordkeeping <\/td>\n<\/tr>\n
135<\/td>\nProcess Monitoring <\/td>\n<\/tr>\n
137<\/td>\nSpecial Operating Considerations for Various System Designs <\/td>\n<\/tr>\n
138<\/td>\nMaintaining Productivity <\/td>\n<\/tr>\n
144<\/td>\nMaintaining Filtrate Quality <\/td>\n<\/tr>\n
146<\/td>\nTroubleshooting and Proactive Ideas <\/td>\n<\/tr>\n
148<\/td>\nTraining
Safety
References <\/td>\n<\/tr>\n
150<\/td>\nChapter 8 Membrane Applications <\/td>\n<\/tr>\n
151<\/td>\nMembrane Filtration For Turbidity and Microbial Removal in Early Plants <\/td>\n<\/tr>\n
152<\/td>\nIntegrated Process Applications Emergence of the Predominant Treatment
\n Approach <\/td>\n<\/tr>\n
153<\/td>\nPretreatment by Low-Pressure Membranes <\/td>\n<\/tr>\n
154<\/td>\nMidtreatment Process by Low-Pressure Membranes <\/td>\n<\/tr>\n
155<\/td>\nFinal Treatment by Low-Pressure Membranes <\/td>\n<\/tr>\n
163<\/td>\nSummary
References <\/td>\n<\/tr>\n
166<\/td>\nChapter 8A San Jose Water Company, Saratoga Water Treatment Plant\u2014Microfiltration
\n of Variable-Quality River Water <\/td>\n<\/tr>\n
170<\/td>\nChapter 8B Lyonnaise Water, Bernay Water Treatment Plant,
\n Bernay, France\u2014One of the World\u2019s First Ultrafiltration (UF)
\n Membrane Facilities <\/td>\n<\/tr>\n
174<\/td>\nChapter 8C Coliban Water, Sandhurst Water Treatment Plant\u2014
\n Submerged Microfiltration of Reservoir Water <\/td>\n<\/tr>\n
178<\/td>\nChapter 8D Barrow Utilities Electric Cooperative Inc.\u2014Microfiltration\/
\n Nanofiltration Dual-Membrane Plant <\/td>\n<\/tr>\n
182<\/td>\nChapter 8E Brazos River Authority, Lake Granbury Surface Water
\n Advanced Treatment System\u2014Ultrafiltration\/Reverse Osmosis
\n Integrated Membrane System <\/td>\n<\/tr>\n
188<\/td>\nChapter 8F Seekonk, Massachusetts\u2014Iron and Manganese
\n Removal Plant <\/td>\n<\/tr>\n
192<\/td>\nChapter 8G Fallon Paiute-Shoshone Tribe\u2014Coagulation\/Microfiltration
\n Facility for Arsenic Removal <\/td>\n<\/tr>\n
196<\/td>\nChapter 8H Lakeview Water Treatment Plant Region of Peel, Ontario,
\n Canada\u2014Meeting Water-Quality Objectives Through MF <\/td>\n<\/tr>\n
204<\/td>\nChapter 8I Pittsburgh, Pennsylvania, Facility\u2014Polishing of Finished
\n Water Reservoir Water Using Microfiltration <\/td>\n<\/tr>\n
208<\/td>\nChapter 9 Cost of Microfiltration and Ultrafiltration Membrane Systems <\/td>\n<\/tr>\n
209<\/td>\nProject Management and Administrative Costs <\/td>\n<\/tr>\n
210<\/td>\nMembrane Procurement Costs <\/td>\n<\/tr>\n
211<\/td>\nMembrane System Capital Cost Considerations <\/td>\n<\/tr>\n
212<\/td>\nAdditional Capital Cost Considerations <\/td>\n<\/tr>\n
213<\/td>\nOperational Costs <\/td>\n<\/tr>\n
215<\/td>\nGeneralized Membrane Equipment Costs <\/td>\n<\/tr>\n
217<\/td>\nGeneralized Construction and Installation Costs <\/td>\n<\/tr>\n
218<\/td>\nOperations and Maintenance Costs <\/td>\n<\/tr>\n
219<\/td>\nSummary <\/td>\n<\/tr>\n
220<\/td>\nChapter 10 Residuals and Their Management
Microfiltration\/Ultrafiltration Residuals <\/td>\n<\/tr>\n
225<\/td>\nMF\/UF Residuals Management Mostly States\u2019 Responsibility <\/td>\n<\/tr>\n
228<\/td>\nLocation a Factor in Choosing Disposal Methods <\/td>\n<\/tr>\n
229<\/td>\nSome Backwash Disposal and Treatment Methods More Common Than Others <\/td>\n<\/tr>\n
231<\/td>\nChemicals a Factor in Handling Cleaning Solutions <\/td>\n<\/tr>\n
232<\/td>\nSummary <\/td>\n<\/tr>\n
233<\/td>\nRecommendations
References <\/td>\n<\/tr>\n
236<\/td>\nChapter 11 Future Trends in Low-Pressure Membrane Filtration
Background <\/td>\n<\/tr>\n
237<\/td>\nSurvey Description <\/td>\n<\/tr>\n
246<\/td>\nIndex <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

AWWA M53 Microfiltration and Ultrafiltration Membranes for Drinking Water, Second edition<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
AWWA<\/b><\/a><\/td>\n2016<\/td>\n255<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":155566,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2651],"product_tag":[],"class_list":{"0":"post-155562","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-awwa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/155562","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/155566"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=155562"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=155562"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=155562"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}