{"id":222225,"date":"2024-10-19T14:25:31","date_gmt":"2024-10-19T14:25:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-99722015\/"},"modified":"2024-10-25T08:00:48","modified_gmt":"2024-10-25T08:00:48","slug":"bs-en-iso-99722015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-99722015\/","title":{"rendered":"BS EN ISO 9972:2015"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1\tScope 2\tNormative references 3\tTerms, definitions, and symbols 3.1\tTerms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3.2\tSymbols <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4\tApparatus 4.1\tGeneral 4.2\tEquipment 4.2.1\tAir-moving equipment 4.2.2\tPressure-measuring device 4.2.3\tAir flow rate measuring system 4.2.4\tTemperature-measuring device 5\tMeasurement procedure 5.1\tMeasurement conditions 5.1.1\tGeneral <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.1.2\tMeasured extent 5.1.3\tTime of measurement 5.2\tPreparation 5.2.1\tBuilding preparation methods 5.2.2\tHeating, ventilation and air conditioning systems and other building equipment <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.2.3\tIntentional openings in the envelope <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2.4\tOpenings inside the measured extent 5.2.5\tAir-moving equipment 5.2.6\tPressure measuring devices <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.3\tSteps of the procedure 5.3.1\tPreliminary check 5.3.2\tTemperature and wind conditions 5.3.3\tZero-flow pressure difference 5.3.4\tPressure difference sequence <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6\tExpression of results 6.1\tReference values 6.1.1\tInternal volume 6.1.2\tEnvelope area <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.1.3\tNet floor area 6.2\tCalculation of the air leakage rate <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.3\tDerived quantities 6.3.1\tGeneral 6.3.2\tAir change rate at reference pressure difference 6.3.3\tSpecific leakage rate (envelope) <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.3.4\tSpecific leakage rate (floor) 6.3.5\tEffective leakage area 6.3.6\tSpecific effective leakage area (envelope) 6.3.7\tSpecific effective leakage area (floor) <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7\tTest report 8\tUncertainty 8.1\tGeneral <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 8.2\tReference value 8.3\tOverall uncertainty <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Annex\u00a0A (informative) Description of equipment used to pressurize buildings <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex\u00a0B (informative) Dependence of air density on temperature, dew point,and barometric pressure <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex\u00a0C (informative) Recommended procedure for estimating uncertaintyin derived quantities <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex\u00a0D (informative) Beaufort scale of wind (extract) <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex\u00a0E (informative) Detection of the leakage location <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Thermal performance of buildings. Determination of air permeability of buildings. Fan pressurization method<\/b><\/p>\n |