{"id":223604,"date":"2024-10-19T14:31:24","date_gmt":"2024-10-19T14:31:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-5950-82003\/"},"modified":"2024-10-25T08:14:24","modified_gmt":"2024-10-25T08:14:24","slug":"bs-5950-82003","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-5950-82003\/","title":{"rendered":"BS 5950-8:2003"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nBRITISH STANDARD <\/td>\n<\/tr>\n
2<\/td>\nCommittees responsible for this British\ufffdStandard <\/td>\n<\/tr>\n
3<\/td>\nContents <\/td>\n<\/tr>\n
7<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
8<\/td>\n3 Terms and definitions
3.1critical element
3.2 design temperature
3.3 element
3.4 fire exposure
3.5 fire protection material
3.6 fire resistance
3.7 insulation
3.8 integrity
3.9 limiting temperature
3.10 load capacity
3.11 natural fires <\/td>\n<\/tr>\n
9<\/td>\n3.12 standard fire
3.13 standard fire test
3.14 structural member
3.15 thermal expansion
4 Major symbols
5 General principles
5.1 Aims of fire precautions
5.2 Structural performance requirements <\/td>\n<\/tr>\n
10<\/td>\n5.3 Methods of design
5.4 Fire exposure
5.5 Thermal response
5.6 Structural response
6 Structural members in fire
6.1 Properties at elevated temperature <\/td>\n<\/tr>\n
11<\/td>\nFigure 1 Thermal elongation of steel <\/td>\n<\/tr>\n
12<\/td>\nFigure 2 Variation of specific heat with temperature for steel <\/td>\n<\/tr>\n
13<\/td>\nFigure 3 Variation of thermal conductivity with temperature for steel <\/td>\n<\/tr>\n
15<\/td>\nFigure 4 Variation of thermal elongation with temperature for normal weight and lightweight concrete <\/td>\n<\/tr>\n
16<\/td>\nFigure 5 Variation of specific heat with temperature for normal weight and lightweight\ufffdconcrete <\/td>\n<\/tr>\n
17<\/td>\nFigure 6 Variation of thermal conductivity with temperature for normal weight and lightweight concrete
6.2 Strength retention factors <\/td>\n<\/tr>\n
18<\/td>\nTable 1
Table 2 <\/td>\n<\/tr>\n
19<\/td>\nTable 3
Table 4
6.3 Strain levels <\/td>\n<\/tr>\n
20<\/td>\n7 Fire limit states
7.1 General
Table 5
7.2 Material strength factors
7.3 Performance criteria <\/td>\n<\/tr>\n
21<\/td>\n7.4 Bracing members
7.5 Re-use of steel after a fire
8 Evaluation of fire performance
8.1 General
8.2 Section factor <\/td>\n<\/tr>\n
22<\/td>\n8.3 Fire performance derived from testing <\/td>\n<\/tr>\n
23<\/td>\nTable 6 <\/td>\n<\/tr>\n
24<\/td>\nTable 7 <\/td>\n<\/tr>\n
25<\/td>\n8.4 Fire performance derived from calculation <\/td>\n<\/tr>\n
27<\/td>\nTable 8 <\/td>\n<\/tr>\n
28<\/td>\nTable 9 <\/td>\n<\/tr>\n
29<\/td>\nTable 10 <\/td>\n<\/tr>\n
31<\/td>\n8.5 Portal frames
8.6 Concrete-filled hollow section columns
Table 11
8.7 Water-filled structures <\/td>\n<\/tr>\n
32<\/td>\n8.8 External bare steel
8.9 Floor and roof slabs <\/td>\n<\/tr>\n
33<\/td>\nTable 12
Figure 7 Measurement of depth into concrete slab
Figure 8 Insulation thickness for trapezoidal profiled steel sheets <\/td>\n<\/tr>\n
34<\/td>\nFigure 9Insulation thickness for re-entrant profiled steel sheets
Table 13
Table 14
Figure 10 Effect of beam deflection on a fire-resisting wall <\/td>\n<\/tr>\n
35<\/td>\n8.10 Walls
8.11 Roofs
8.12 Ceilings <\/td>\n<\/tr>\n
37<\/td>\nAnnex A (normative) Strength retention factors for cold formed steels complying with BS\ufffdEN\ufffd10143
Table A.1
Annex B(normative) Re-use of steel after a fire <\/td>\n<\/tr>\n
39<\/td>\nAnnex C (normative) Simplified method of calculation for beams with shelf angles <\/td>\n<\/tr>\n
40<\/td>\nTemperature profile
Embedded steelwork
Figure C.1 Temperature blocks for beams with shelf angles <\/td>\n<\/tr>\n
41<\/td>\nTable C.1
Table C.2
Figure C.2 Definition of dimension <\/td>\n<\/tr>\n
42<\/td>\nFigure C.3 Definition of blocks 4, 5 and 6 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Structural use of steelwork in building – Code of practice for fire resistant design<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2003<\/td>\n44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":223606,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[240,2641],"product_tag":[],"class_list":{"0":"post-223604","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-50","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/223604","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/223606"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=223604"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=223604"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=223604"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}