{"id":336950,"date":"2024-10-19T23:33:27","date_gmt":"2024-10-19T23:33:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-181442003\/"},"modified":"2024-10-25T22:35:09","modified_gmt":"2024-10-25T22:35:09","slug":"bs-iso-181442003","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-181442003\/","title":{"rendered":"BS ISO 18144:2003"},"content":{"rendered":"

This International Standard specifies a method for the sampling and determination of respirable suspended particles (RSP) and for the estimation of the RSP fraction attributable to environmental tobacco smoke (ETS). This method is applicable to personal and area sampling. This method is compatible with the determinations of gravimetric RSP, ultraviolet particulate matter (UVPM) and fluorescent particulate matter (FPM), which are also used to estimate the contribution of ETS to RSP.<\/p>\n

\n

NOTE See ISO 15593[3]<\/sup> for details.<\/p>\n<\/blockquote>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
3<\/td>\nTitlePage – Environmental tobacco smoke\ufffd\u2014 Estimation of its contribution to respirable suspended … <\/td>\n<\/tr>\n
5<\/td>\nTableofContent – Contents Page <\/td>\n<\/tr>\n
6<\/td>\nForeword – Foreword <\/td>\n<\/tr>\n
7<\/td>\nIntroduction – Introduction <\/td>\n<\/tr>\n
9<\/td>\nScope – 1\ufffd\ufffd\ufffd Scope
NormativeReference – 2\ufffd\ufffd\ufffd Normative references <\/td>\n<\/tr>\n
10<\/td>\nClause1 – 4\ufffd\ufffd\ufffd Principle
Clause1 – 5\ufffd\ufffd\ufffd Limits and detection
Clause1 – 6\ufffd\ufffd\ufffd Reagents
UntitledSubclause2 – 6.1\ufffd\ufffd\ufffd Acetonitrile
UntitledSubclause2 – 6.2\ufffd\ufffd\ufffd Methanol
UntitledSubclause2 – 6.3\ufffd\ufffd\ufffd Solanesol
UntitledSubclause2 – 6.4\ufffd\ufffd\ufffd Helium
UntitledSubclause2 – 6.5\ufffd\ufffd\ufffd Solanesol standard solutions
UntitledSubclause3 – 6.5.1\ufffd\ufffd\ufffd Primary standard of solanesol
UntitledSubclause3 – 6.5.2\ufffd\ufffd\ufffd Secondary standard of solanesol
UntitledSubclause3 – 6.5.3\ufffd\ufffd\ufffd Tertiary standard of solanesol <\/td>\n<\/tr>\n
11<\/td>\nUntitledSubclause3 – 6.5.4\ufffd\ufffd\ufffd Working standards of solanesol
Clause1 – 7\ufffd\ufffd\ufffd Apparatus
UntitledSubclause2 – 7.1\ufffd\ufffd\ufffd Sample collection system
UntitledSubclause3 – 7.1.1\ufffd\ufffd\ufffd Polytetrafluoroethylene (PTFE) membrane filter
UntitledSubclause3 – 7.1.2\ufffd\ufffd\ufffd Filter cassette
UntitledSubclause3 – 7.1.3\ufffd\ufffd\ufffd Bubble flowmeter
UntitledSubclause3 – 7.1.4\ufffd\ufffd\ufffd Personal sampling pump
UntitledSubclause3 – 7.1.5\ufffd\ufffd\ufffd Inertial impactor
UntitledSubclause3 – 7.1.6\ufffd\ufffd\ufffd Stopcock grease
UntitledSubclause2 – 7.2\ufffd\ufffd\ufffd Analytical system
UntitledSubclause3 – 7.2.1\ufffd\ufffd\ufffd High-performance liquid chromatography (HPLC) system
UntitledSubclause3 – 7.2.2\ufffd\ufffd\ufffd HPLC column
UntitledSubclause3 – 7.2.3\ufffd\ufffd\ufffd Guard cartridge column
UntitledSubclause3 – 7.2.4\ufffd\ufffd\ufffd Sample containers
UntitledSubclause2 – 7.3\ufffd\ufffd\ufffd Dispensing pipettes
UntitledSubclause2 – 7.4\ufffd\ufffd\ufffd Filter forceps
UntitledSubclause2 – 7.5\ufffd\ufffd\ufffd Wrist-action shaking device
UntitledSubclause2 – 7.6\ufffd\ufffd\ufffd One-mark pipettes <\/td>\n<\/tr>\n
12<\/td>\nUntitledSubclause2 – 7.7\ufffd\ufffd\ufffd One-mark volumetric flasks
Clause1 – 8\ufffd\ufffd\ufffd Sampling procedure
Subclause2 – 8.1\ufffd\ufffd\ufffd Calibration of air pumping system
Subclause2 – 8.2\ufffd\ufffd\ufffd Sample collection <\/td>\n<\/tr>\n
13<\/td>\nClause1 – 9\ufffd\ufffd\ufffd Analytical procedure
Subclause2 – 9.1\ufffd\ufffd\ufffd Preparation of samples and blanks
Subclause2 – 9.2\ufffd\ufffd\ufffd Determination of solanesol
Subclause3 – 9.2.1\ufffd\ufffd\ufffd Setting up the apparatus <\/td>\n<\/tr>\n
14<\/td>\nSubclause3 – 9.2.2\ufffd\ufffd\ufffd Analysis of samples and blanks
Subclause3 – 9.2.3\ufffd\ufffd\ufffd Constructing the solanesol calibration curve <\/td>\n<\/tr>\n
15<\/td>\nClause1 – 10\ufffd\ufffd\ufffd Expression of results
Subclause2 – 10.1\ufffd\ufffd\ufffd Calculation of solanesol contents
Subclause3 – 10.1.1\ufffd\ufffd\ufffd Solanesol content in the test solution
Subclause3 – 10.1.2\ufffd\ufffd\ufffd Solanesol content in the air <\/td>\n<\/tr>\n
16<\/td>\nSubclause2 – 10.2\ufffd\ufffd\ufffd ETS-PM contribution to RSP as estimated by solanesol
Subclause3 – 10.2.1\ufffd\ufffd\ufffd Calculation of Sol-PM
Subclause3 – 10.2.2\ufffd\ufffd\ufffd Apportionment of RSP as estimated by Sol-PM
Clause1 – 11\ufffd\ufffd\ufffd Laboratory performance criteria and quality assurance
Clause1 – 12\ufffd\ufffd\ufffd Repeatability and reproducibility <\/td>\n<\/tr>\n
17<\/td>\nClause1 – 13\ufffd\ufffd\ufffd Test report <\/td>\n<\/tr>\n
18<\/td>\nAnnexInformative – Laboratory performance criteria: Quality assurance measures
Clause1 – A.1\ufffd\ufffd\ufffd Standard operating procedures (SOPs)
UntitledSubclause2 – A.1.1\ufffd\ufffd\ufffd Users should generate SOPs describing and documenting the following…
UntitledSubclause2 – A.1.2\ufffd\ufffd\ufffd The SOPs should provide specific, step-by-step instructions and sho…
UntitledSubclause2 – A.1.3\ufffd\ufffd\ufffd Solanesol is typically not detected in sample blanks. Detectable qu…
UntitledSubclause2 – A.1.4\ufffd\ufffd\ufffd Periodically, wipe clean the surface of the inertial impactor and a…
UntitledSubclause2 – A.1.5\ufffd\ufffd\ufffd In the event that an initial sample result is above the calibration…
Clause1 – A.2\ufffd\ufffd\ufffd Calibration of personal sampling pumps
UntitledSubclause2 – A.2.1\ufffd\ufffd\ufffd Calibrate sampling pumps at the beginning and at the conclusion of …
UntitledSubclause2 – A.2.2\ufffd\ufffd\ufffd Set the pump flow controller using a bubble flowmeter or mass flowm…
Clause1 – A.3\ufffd\ufffd\ufffd Method sensitivity, precision and linearity
UntitledSubclause2 – A.3.1\ufffd\ufffd\ufffd The sensitivity of this method is demonstrated by the detection lim…
UntitledSubclause2 – A.3.2\ufffd\ufffd\ufffd Determining repeatability and reproducibility ensures method precis…
UntitledSubclause2 – A.3.3\ufffd\ufffd\ufffd Non-linearity in the calibration curve may occur at concentrations …
Clause1 – A.4\ufffd\ufffd\ufffd Method modification
UntitledSubclause2 – A.4.1\ufffd\ufffd\ufffd The sampling period described in this method may be extended beyond <\/td>\n<\/tr>\n
19<\/td>\nUntitledSubclause2 – A.4.2\ufffd\ufffd\ufffd The flow rate of air through the filter may be increased up to
UntitledSubclause2 – A.4.3\ufffd\ufffd\ufffd The test solution resulting from the procedure described herein is …
Clause1 – A.5\ufffd\ufffd\ufffd Safety
UntitledSubclause2 – A.5.1\ufffd\ufffd\ufffd If spilling of solvent or any of the reagents occurs, take quick an…
UntitledSubclause2 – A.5.2\ufffd\ufffd\ufffd When preparing standards, as with handling any chemicals, avoid con… <\/td>\n<\/tr>\n
20<\/td>\nBibliography – Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Environmental tobacco smoke. Estimation of its contribution to respirable suspended particles. Method based on solanesol<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2009<\/td>\n24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":336960,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[203,2641],"product_tag":[],"class_list":{"0":"post-336950","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-040-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/336950","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/336960"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=336950"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=336950"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=336950"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}