{"id":34066,"date":"2024-10-17T04:21:11","date_gmt":"2024-10-17T04:21:11","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e181-3\/"},"modified":"2024-10-24T14:44:34","modified_gmt":"2024-10-24T14:44:34","slug":"astm-e181-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e181-3\/","title":{"rendered":"ASTM-E181"},"content":{"rendered":"<\/p>\n
1.1 These methods cover general procedures for the calibration of radiation detectors and the analysis of radionuclides. For each individual radionuclide, one or more of these methods may apply.<\/p>\n
1.2 These methods are concerned only with specific radionuclide measurements. The chemical and physical properties of the radionuclides are not within the scope of this standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Document Terminology <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Scope Apparatus Summary of Methods Preparation of Apparatus Calibration Procedure <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Measurement of Gamma-Ray Emission Rate of the Sample FIG. 1 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Performance Testing Sources of Uncertainty Precautions and Tests <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Scope FIG. 2 <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Apparatus Preparation of Apparatus Multichannel Analyzer (MCA) Counting for Simple Spectra <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Multichannel Analyzer (MCA) Counting for Complex Spectra <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Performance Testing Precautions <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Sources of Uncertainty Scope Summary of Method Apparatus <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Preparation of Apparatus Beta Counting Procedure Calculations <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Scope Summary of Method Apparatus Aluminum Absorption Curve Procedure FIG. 3 <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Calculation Scope Summary of Method Apparatus FIG. 4 <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Preparation of Apparatus Alpha Counting Procedure Calculations for SCA Methods Sources of Uncertainty: SCA Counting Methods Calculations for MCA Methods <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | FIG. 5 <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Scope Summary of Method Interferences Apparatus <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Standardization and Calibration Procedure Calculation Precision and Bias Performance Testing <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | REFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" E181-98(2003) Standard Test Methods for Detector Calibration and Analysis of Radionuclides<\/b><\/p>\n |