{"id":416569,"date":"2024-10-20T06:11:28","date_gmt":"2024-10-20T06:11:28","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-52120-12022-3\/"},"modified":"2024-10-26T11:29:55","modified_gmt":"2024-10-26T11:29:55","slug":"bs-en-iso-52120-12022-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-52120-12022-3\/","title":{"rendered":"BS EN ISO 52120-1:2022"},"content":{"rendered":"
This European Standard specifies: – a structured list of control, building automation and technical building management functions which contribute to the energy performance of buildings; functions have been categorized and structured according to building disciplines and so called Building automation and control (BAC); – a method to define minimum requirements or any specification regarding the control, building automation and technical building management functions contributing to energy efficiency of a building to be implemented in building of different complexities; – a factor based method to get a first estimation of the effect of these functions on typical buildings types and use profiles; – detailed methods to assess the effect of these functions on a given building. Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in EN ISO 52000 1. NOTE 1 In CEN ISO\/TR 52000 2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation. NOTE 2 The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | European foreword Endorsement notice <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4 Symbols, subscripts and abbreviated terms 4.1 Symbols 4.2 Subscripts 4.3 Abbreviated terms <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5 Description of the method 5.1 Output of the method 5.2 General description of the method(s) 5.3 Selection criteria between the methods <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.4 BAC and TBM functions having an impact on the energy performance of buildings <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 5.5 BAC efficiency class <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 5.6 BAC and TBM functions assigned to the BAC efficiency classes <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 5.7 Applying BAC for EnMS and maintaining BAC energy efficiency 5.7.1 General 5.7.2 Applying BAC for EnMS 5.7.3 Maintaining BAC energy efficiency <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 6 Method 1 – Detailed calculation procedure of the BAC contribution to the energy performance of buildings (detailed method) 6.1 Output data <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 6.2 Calculation time intervals <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 6.3 Input data – Source of data 6.4 Calculation procedure 6.4.1 Applicable calculation time interval 6.4.2 Energy performance calculation <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 7 Method 2 – Factor based calculation procedure of the BAC impact on the energy performance of buildings (BAC factor method) 7.1 Output data 7.2 Calculation time interval <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 7.3 Calculation procedure \u2014 Energy calculation 7.3.1 General <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 7.3.2 BAC efficiency factor values <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 7.3.3 Application of the BAC efficiency factors <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 8 Simplified input data correlations 9 Quality control 10 \u200bCompliance check <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Annex A (informative) BAC efficiency factors <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Annex B (normative) Minimum BAC function type requirements <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Annex C (informative) Determination of the BAC efficiency factors <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Annex D (informative) Examples of how to use the BAC function list of ISO 16484-3 to describe functions from this document <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Annex E (informative) Applying BAC for EnMS specified in ISO 50001:2018 <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | Annex F (informative) Maintain BAC energy efficiency <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | Annex G (informative) Control accuracy <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Energy performance of buildings. Contribution of building automation, controls and building management – General framework and procedures<\/b><\/p>\n |