{"id":431566,"date":"2024-10-20T07:28:55","date_gmt":"2024-10-20T07:28:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bicsi-field-guide-3-fiber-2020\/"},"modified":"2024-10-26T14:13:13","modified_gmt":"2024-10-26T14:13:13","slug":"bicsi-field-guide-3-fiber-2020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bicsi\/bicsi-field-guide-3-fiber-2020\/","title":{"rendered":"BICSI Field Guide 3 Fiber 2020"},"content":{"rendered":"

This guide focuses on in-the-field optical fiber cabling installation and maintenance techniques based on applicable codes, standards and industry best practices. Throughout its pages you will find everything likely to come up on the job site, from optical fiber cable classification, splicing, applications, performance specifications, length limitations, termination, troubleshooting, and much more.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nOptical Fiber Field Guide <\/td>\n<\/tr>\n
2<\/td>\nPreface <\/td>\n<\/tr>\n
5<\/td>\nWARNING <\/td>\n<\/tr>\n
6<\/td>\nAcknowledgments <\/td>\n<\/tr>\n
8<\/td>\nIcons, Abbreviations and Acronyms <\/td>\n<\/tr>\n
10<\/td>\nTable of Contents <\/td>\n<\/tr>\n
14<\/td>\nFigures <\/td>\n<\/tr>\n
18<\/td>\nTables <\/td>\n<\/tr>\n
19<\/td>\nExamples <\/td>\n<\/tr>\n
20<\/td>\nSteps <\/td>\n<\/tr>\n
22<\/td>\nOptical Fiber Cabling Media
Optical Fiber Strands <\/td>\n<\/tr>\n
23<\/td>\nMultimode <\/td>\n<\/tr>\n
24<\/td>\nSinglemode <\/td>\n<\/tr>\n
25<\/td>\nCable Construction <\/td>\n<\/tr>\n
26<\/td>\nTight-Buffered Optical Fiber Cable <\/td>\n<\/tr>\n
28<\/td>\nLoose-Tube Optical Fiber Cable <\/td>\n<\/tr>\n
29<\/td>\nRibbon Optical Fiber Cable <\/td>\n<\/tr>\n
30<\/td>\nAir-Blown Optical Fiber Cable
Cabling Performance Classification <\/td>\n<\/tr>\n
33<\/td>\nOptical Fiber Cable and Strand Color Codes <\/td>\n<\/tr>\n
35<\/td>\nCable Construction <\/td>\n<\/tr>\n
36<\/td>\nType CMP
Type CMR <\/td>\n<\/tr>\n
37<\/td>\nType CMG
Type CM
Type CMX
Type CMUC Undercarpet Wires and Cables <\/td>\n<\/tr>\n
38<\/td>\nBandwidth
Dispersion <\/td>\n<\/tr>\n
39<\/td>\nModal Dispersion
Chromatic Dispersion <\/td>\n<\/tr>\n
40<\/td>\nAttenuation
Backbone Fiber Cabling <\/td>\n<\/tr>\n
41<\/td>\nBackbone Fiber Cable Selection
Horizontal Fiber Cabling <\/td>\n<\/tr>\n
43<\/td>\nCentralized Optical Fiber Cabling <\/td>\n<\/tr>\n
44<\/td>\nCentralized Optical Fiber Cabling Distances
Pull-Through Method
Interconnection and Splice Methods <\/td>\n<\/tr>\n
45<\/td>\nPassive Optical Networks (PONs) <\/td>\n<\/tr>\n
48<\/td>\nAir-Blown Optical Fiber Tubes
Installation Conditions
Establishing Optical Fiber Pathway <\/td>\n<\/tr>\n
49<\/td>\nTube Couplers
Tube Management <\/td>\n<\/tr>\n
50<\/td>\nOptical Fiber Cabling Hazards <\/td>\n<\/tr>\n
52<\/td>\nAdditional Considerations for Pulling Fiber Optic Cables <\/td>\n<\/tr>\n
61<\/td>\nTesting Primary Tubes or Tube Bundles
Blowing Optical Fiber Cable <\/td>\n<\/tr>\n
62<\/td>\nTerminate Cable
Perform Pre-termination Functions <\/td>\n<\/tr>\n
65<\/td>\nSteps\u2014Simplex, Zip Cord, and Breakout Cable Preparation <\/td>\n<\/tr>\n
66<\/td>\nSteps\u2014Multifiber Tight-Buffered Cable Preparation
Steps\u2014Loose-Tube Cable Preparation <\/td>\n<\/tr>\n
67<\/td>\nTerminate Cable and Fiber
Steps\u2014Field Polished Connector Installation <\/td>\n<\/tr>\n
68<\/td>\nSteps\u2014Scribing and Polishing the Connector <\/td>\n<\/tr>\n
74<\/td>\nInspecting and Cleaning Optical Fiber Connectors
Inspection Tools <\/td>\n<\/tr>\n
75<\/td>\nMicroscopes <\/td>\n<\/tr>\n
77<\/td>\nInspection Practices <\/td>\n<\/tr>\n
79<\/td>\nCleaning Materials and Methods
Dry Wipes
Dry Swabs <\/td>\n<\/tr>\n
80<\/td>\nSolvents with Wipes or Swabs <\/td>\n<\/tr>\n
81<\/td>\nCleaning Machines
Canned Air
Solvents <\/td>\n<\/tr>\n
85<\/td>\nGeneral Guidelines for Cleaning <\/td>\n<\/tr>\n
87<\/td>\nConnectors
Single\/Double Strand Connectors (Present Usage) <\/td>\n<\/tr>\n
88<\/td>\nArray Connectors <\/td>\n<\/tr>\n
90<\/td>\nLegacy-Style Connectors
Coupling of Optical Fibers <\/td>\n<\/tr>\n
91<\/td>\nOptical Fiber Hardware <\/td>\n<\/tr>\n
92<\/td>\nOptical Fiber Cable Splicing Examples <\/td>\n<\/tr>\n
95<\/td>\nOptical Fiber Strand Preparation <\/td>\n<\/tr>\n
96<\/td>\nMechanical Splicing <\/td>\n<\/tr>\n
98<\/td>\nFusion Splicing <\/td>\n<\/tr>\n
106<\/td>\nTesting and Troubleshooting Optical Fiber Cable
Test Equipment <\/td>\n<\/tr>\n
109<\/td>\nPre-installation Testing <\/td>\n<\/tr>\n
110<\/td>\nAcceptance Testing <\/td>\n<\/tr>\n
114<\/td>\nConfiguration Testing
Preventive Maintenance Testing <\/td>\n<\/tr>\n
115<\/td>\nTest Measurement Documentation <\/td>\n<\/tr>\n
118<\/td>\nTest Scenarios and Considerations <\/td>\n<\/tr>\n
119<\/td>\nAttenuation <\/td>\n<\/tr>\n
122<\/td>\nCircuit Configurations <\/td>\n<\/tr>\n
124<\/td>\nOptical Loss Test Set (OLTS) <\/td>\n<\/tr>\n
125<\/td>\nTest Configuration Methods <\/td>\n<\/tr>\n
126<\/td>\nMode Filter
One Jumper Method Referencing <\/td>\n<\/tr>\n
128<\/td>\nOne Jumper Method Testing
Two Jumper Method Referencing <\/td>\n<\/tr>\n
129<\/td>\nTwo Jumper Method Testing <\/td>\n<\/tr>\n
130<\/td>\nThree Jumper Method Referencing <\/td>\n<\/tr>\n
131<\/td>\nThree Jumper Method Testing <\/td>\n<\/tr>\n
132<\/td>\nOptical Time Domain Reflectometer (OTDR) <\/td>\n<\/tr>\n
133<\/td>\nOptical Time Domain Reflectometer (OTDR) Testing Procedures <\/td>\n<\/tr>\n
134<\/td>\nMicroscope and Interferometer <\/td>\n<\/tr>\n
135<\/td>\nRadius of Curvature <\/td>\n<\/tr>\n
136<\/td>\nOffset of Polish
Optical Fiber Height <\/td>\n<\/tr>\n
138<\/td>\nTroubleshooting Optical Fiber Media
Troubleshooting Methods <\/td>\n<\/tr>\n
141<\/td>\nVerifying the Problem <\/td>\n<\/tr>\n
142<\/td>\nIsolating the Problem <\/td>\n<\/tr>\n
143<\/td>\nRepairing the Problem
Testing the Repaired System <\/td>\n<\/tr>\n
147<\/td>\nTypical OTDR Fault Presentations
Reflective Break <\/td>\n<\/tr>\n
148<\/td>\nNon-reflective Break <\/td>\n<\/tr>\n
149<\/td>\nDefective Splices <\/td>\n<\/tr>\n
152<\/td>\nIndex
A
B
C <\/td>\n<\/tr>\n
153<\/td>\nD
E
F
H <\/td>\n<\/tr>\n
154<\/td>\nI
L
M
O <\/td>\n<\/tr>\n
155<\/td>\nP
R
S <\/td>\n<\/tr>\n
156<\/td>\nT
V
Z <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ICT Installation Practices Field Guides: Volume 3 \u2013 Optical Fiber Cabling, 1st Edition<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BICSI<\/b><\/a><\/td>\n2020<\/td>\n156<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":431572,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2681],"product_tag":[],"class_list":{"0":"post-431566","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bicsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/431566","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/431572"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=431566"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=431566"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=431566"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}