{"id":72856,"date":"2024-10-17T16:24:58","date_gmt":"2024-10-17T16:24:58","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/awwa-c500-2009\/"},"modified":"2024-10-24T19:08:21","modified_gmt":"2024-10-24T19:08:21","slug":"awwa-c500-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/awwa\/awwa-c500-2009\/","title":{"rendered":"AWWA C500 2009"},"content":{"rendered":"

This standard describes iron-body, brass-mounted, nonrising-stem (NRS) gate valves, including tapping gate valves, 3-in. (75-mm) NPS through 48-in. (1,200-mm) NPS, and outside screw and yoke (OS&Y) rising-stem gate valves, 3-in. (75-mm) NPS through 24-in. (600 mm) NPS, with either double-disc gates having parallel or inclined seats, or solid-wedge gates. These valves are suitable for use in approximately level settings in water systems. These valves are intended for applications where fluid velocities do not exceed 16 ft\/sec (4.9 m\/s) when the valve is in the full open position. 1.1.1 Valve pressure ratings. The minimum design working water pres-sure shall be 200 psig (1,380 kPa) for valves 12-in. (300-mm) NPS and smaller, and 150 psig (1,050 kPa) for valves with diameters of 14-in. (350-mm) NPS and larger. 1.1.2 Conditions and materials not described. This standard is not intended to describe special conditions of gate-valve installation or operation such as: built-in power drive, installation in unusually corrosive soil, conveyance of unusually corrosive water, or excessive water hammer, or operation in a throttled position. Such conditions are beyond the intended scope of this standard and require special consideration in design and construction. Joint accessories for end connections, such as bolts, gaskets, glands, follower rings, and so forth, are not described in this standard.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI\/AWWA C500-09 <\/td>\n<\/tr>\n
3<\/td>\nCommittee Personnel <\/td>\n<\/tr>\n
5<\/td>\nContents <\/td>\n<\/tr>\n
7<\/td>\nForeword
I. Introduction. <\/td>\n<\/tr>\n
9<\/td>\nII. Special Issues. <\/td>\n<\/tr>\n
10<\/td>\nIII. Use of This Standard. <\/td>\n<\/tr>\n
11<\/td>\nIV. Major Revisions. <\/td>\n<\/tr>\n
12<\/td>\nV. Comments. <\/td>\n<\/tr>\n
13<\/td>\nAWWA Standard Metal-Seated Gate Valves
\nfor Water Supply Service
\n
SECTION 1: GENERAL
Sec. 1.1 Scope <\/td>\n<\/tr>\n
14<\/td>\nSec. 1.2 Purpose
Sec. 1.3 Application
SECTION 2: REFERENCES <\/td>\n<\/tr>\n
16<\/td>\nSECTION 3: DEFINITIONS <\/td>\n<\/tr>\n
17<\/td>\nSECTION 4: REQUIREMENTS
Sec. 4.1 Data to Be Supplied <\/td>\n<\/tr>\n
18<\/td>\nSec. 4.2 Materials <\/td>\n<\/tr>\n
21<\/td>\nSec. 4.3 General Design
Table 1 Valve stem input torque <\/td>\n<\/tr>\n
22<\/td>\nTable 2 Minimum thickness of valve body and bonnet
Sec. 4.4 Detailed Design <\/td>\n<\/tr>\n
24<\/td>\nTable 3 Inside diameter (ID) of hub ends (bell and spigot) <\/td>\n<\/tr>\n
25<\/td>\nTable 4 Minimum thickness for ductile-iron connecting end flanges <\/td>\n<\/tr>\n
26<\/td>\nTable 5 Excess flange thickness <\/td>\n<\/tr>\n
27<\/td>\nTable 6 Copper alloys\u2014stems, gates, stem nuts, and thrust collars <\/td>\n<\/tr>\n
30<\/td>\nTable 7 Minimum diameter of stem and minimum number of turns to open <\/td>\n<\/tr>\n
31<\/td>\nTable 8 Stainless-steel valve stem alloys <\/td>\n<\/tr>\n
33<\/td>\nTable 9 Diameter of handwheels <\/td>\n<\/tr>\n
34<\/td>\nTable 10 Gear ratios <\/td>\n<\/tr>\n
35<\/td>\nTable 11 Size requirements of bypasses
Sec. 4.5 Fabrication
SECTION 5: VERIFICATION
Sec. 5.1 Testing <\/td>\n<\/tr>\n
36<\/td>\nTable 12 Valve stem input torque <\/td>\n<\/tr>\n
37<\/td>\nSec. 5.2 Plant Inspection
SECTION 6: DELIVERY
Sec. 6.1 Marking <\/td>\n<\/tr>\n
38<\/td>\nSec. 6.2 Preparation for Shipment
Sec. 6.3 Affidavit of Compliance <\/td>\n<\/tr>\n
39<\/td>\nAPPENDIX A
SECTION A.1: GENERAL
SECTION A.2: UNLOADING
SECTION A.3: INSPECTION PRIOR TO
\nINSTALLATION <\/td>\n<\/tr>\n
40<\/td>\nSECTION A.4: STORAGE
SECTION A.5: INSTALLATION
Sec. A.5.1 Bolts
Sec. A.5.2 Underground Installation <\/td>\n<\/tr>\n
41<\/td>\nSec. A.5.3 Aboveground Installations
Sec. A.5.4 Inspection <\/td>\n<\/tr>\n
42<\/td>\nSec. A.5.5 Testing
Sec. A.5.6 Records
Sec. A.5.7 Application Hazards <\/td>\n<\/tr>\n
43<\/td>\nSECTION A.6: INSPECTION AND MAINTENANCE
Sec. A.6.1 Inspection <\/td>\n<\/tr>\n
44<\/td>\nSec. A.6.2 Record Keeping
SECTION A.7: REPAIRS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

AWWA C500-09: Metal Seated Gate Valves For Water Supply Service<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
AWWA<\/b><\/a><\/td>\n2009<\/td>\n48<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":72857,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2651],"product_tag":[],"class_list":{"0":"post-72856","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-awwa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/72856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/72857"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=72856"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=72856"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=72856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}